Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Dimensionality and Background Cancellation in Energy Selective X-Ray Imaging
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk bildfysik.ORCID-id: 0000-0003-1428-8351
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk bildfysik.ORCID-id: 0000-0002-5092-8822
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk bildfysik.ORCID-id: 0000-0002-6465-6370
(engelsk)Manuskript (preprint) (Annet vitenskapelig)
Abstract [en]

Purpose: The set of linear attenuation coefficients that belong to materials in the human body is commonly assumed to be spanned by two basis functions in the range of clinical x-ray energies, even though there is evidence that the dimensionality of this set is greater than two. It has not yet been clear that the use of a third basis function could be beneficial in absence of contrast agents.

Approach: In this work, the choice of the number of basis functions used in the basis decomposition method is studied for the task of producing an image where a third material is separated from a background of two other materials, in a case where none of the materials have a K-edge in the range of considered x-ray energies (20-140 keV). The case of separating iron from mixtures of liver and adipose tissue is studied with a simulated phantom which incorporates random and realistic tissue variability.

Results: Inclusion of a third basis function improves the quantitative estimate of iron concentration by several orders of magnitude in terms of mean squared error in the resulting image.

Conclusions: The inclusion of a third basis function in the basis decomposition is essential for the studied imaging task and could have potential application for quantitative estimation of iron concentration from material decomposed images.

Emneord [en]
Energy-resolved computed tomography (CT), basis decomposition, dimensionality, background cancellation, tissue modelling
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-319190DOI: 10.48550/arXiv.2208.05362OAI: oai:DiVA.org:kth-319190DiVA, id: diva2:1699380
Forskningsfinansiär
Familjen Erling-Perssons Stiftelse
Merknad

QC 20221003

Tilgjengelig fra: 2022-09-27 Laget: 2022-09-27 Sist oppdatert: 2022-10-03bibliografisk kontrollert
Inngår i avhandling
1. Spectral Photon-Counting Computed Tomography with Silicon Detectors: New Models and Applications
Åpne denne publikasjonen i ny fane eller vindu >>Spectral Photon-Counting Computed Tomography with Silicon Detectors: New Models and Applications
2022 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

X-ray computed tomography (CT) is a widely used imaging modality that enables visualization of nearly every part of the human body. It is used for diagnosis of disease and injury as well as medical treatment planning. The vast majority of CT scanners in clinical use today have energy-integrating x-ray detectors, which measure the total incident energy in a given measurement.Spectral photon-counting detectors operate by counting individual photons and measuring their energy, and are expected to yield the next major advance in CT, with improvements in spatial resolution, dose efficiency, material differentiation and quantitative imaging capabilities compared to the current state-of-the-art.

In this Thesis, a set of new models and applications for a spectral photon-counting silicon detector developed for CT is investigated. The first part of the Thesis is dedicated to the modeling of spectral photon-counting silicon detectors. A new statistical model for the effects of pulse pileup is presented. Also, the effects on image quality from intra-detector Compton scatter in silicon detectors are investigated via spatio-energetic modeling. In the second part of the Thesis, potential applications for spectral photon-counting detectors are investigated. An experimental study of ex vivo CT imaging of an excised human heart with calcified plaque is presented. It demonstrates the feasibility of unconstrained projection-based three-material decomposition with iodine as a third basis material and explores the potential improvements in spatial resolution and material differentiation that can be achieved with a spectral photon-counting silicon detector compared to a conventional dual-energy CTsystem. Two other applications are investigated with simulations: a method for reconstructing CT images from spectral photon-counting CT data that accurately mimic conventional CT images; and a method for estimating iron concentration in mixtures of liver and adipose tissue when using three basis functions instead of only two to describe the linear attenuation coefficient of tissues in the human body. 

Although the methods presented in this Thesis have been specifically developed for a spectral photon-counting silicon detector, they are also applicable for other types of photon-counting detectors.

sted, utgiver, år, opplag, sider
Stockholm: KTH Royal Institute of Technology, 2022. s. 49
Serie
TRITA-SCI-FOU ; 2022:51
Emneord
photon-counting, spectral computed tomography, material decomposition, pulse pileup, Compton scatter, image formation, fotonräknande, spektral datortomografi, materialbasupdelning, pulsöverlagring, Comptonspridning, bildbildning
HSV kategori
Forskningsprogram
Fysik
Identifikatorer
urn:nbn:se:kth:diva-319191 (URN)978-91-8040-369-6 (ISBN)
Disputas
2022-10-21, FD5, AlbaNova University Center, Roslagstullsbacken 21, Stockholm, 10:15 (engelsk)
Opponent
Veileder
Forskningsfinansiär
Familjen Erling-Perssons Stiftelse
Merknad

CQ20220929

Tilgjengelig fra: 2022-09-29 Laget: 2022-09-27 Sist oppdatert: 2025-02-10bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Grönberg, FredrikPersson, MatsBornefalk, Hans

Søk i DiVA

Av forfatter/redaktør
Grönberg, FredrikPersson, MatsBornefalk, Hans
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 122 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf