Collaborative Emergency Control Strategy Providing Transient Stability after HVDC-link Blocking
North China Electric Power University, School of Electrical and Electronic Engineering, Beijing, China.
KTH, Skolan för elektroteknik och datavetenskap (EECS), Elektroteknik, Elkraftteknik.ORCID-id: 0000-0002-1755-1365
North China Electric Power University, School of Electrical and Electronic Engineering, Beijing, China.
North China Electric Power University, School of Electrical and Electronic Engineering, Beijing, China.
2022 (engelsk)Inngår i: EI2 2022: 6th IEEE Conference on Energy Internet and Energy System Integration, Institute of Electrical and Electronics Engineers (IEEE) , 2022, s. 1051-1056Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Continuous commutation failures of line-commutated high-voltage direct current converter caused by AC faults lead to the blocking of HVDC-link. This may seriously threaten the stability of post-fault power system. Therefore, a collaborative emergency control strategy making use of DC power support is presented to guarantee transient stability after HVDC-link blocking. Firstly, the control enabling criterion is defined based on the variation characteristics of the phase trajectory slope during the first swing, while the analytical equation between the needed control quantity and the system parameters is derived. Secondly, the mathematical relation between the provided control quantity and the number of HVDC-links participating in the power support is deduced, and the participation sequence is determined on the basis of the post-fault stable equilibrium points. Additionally, the time delay of the whole implementation is considered. Finally, the effectiveness of presented control strategy is validated using the improved IEEE 68-bus AC/DC hybrid power system.

sted, utgiver, år, opplag, sider
Institute of Electrical and Electronics Engineers (IEEE) , 2022. s. 1051-1056
Emneord [en]
Continuous commutation failures, DC power support, Emergency control, HVDC-link blocking, Transient stability
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-335710DOI: 10.1109/EI256261.2022.10117100Scopus ID: 2-s2.0-85160206610OAI: oai:DiVA.org:kth-335710DiVA, id: diva2:1795041
Konferanse
6th IEEE Conference on Energy Internet and Energy System Integration, EI2 2022, Chengdu, China, Nov 11 2022 - Nov 13 2022
Merknad

Part of ISBN 9798350347159

QC 20230907

Tilgjengelig fra: 2023-09-07 Laget: 2023-09-07 Sist oppdatert: 2023-09-07bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Nee, Hans-Peter

Søk i DiVA

Av forfatter/redaktør
Nee, Hans-Peter
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 75 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf