Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform
Univ Oxford, Oxford OX1 3RH, England..
Harish-Chandra Research Institute, Jhunsi, Allahabad, 211 019, India.ORCID-id: 0000-0002-6071-8546
Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA..
Rekke forfattare: 9912020 (engelsk)Inngår i: Journal of Instrumentation, E-ISSN 1748-0221, Vol. 15, nr 12, artikkel-id P12004Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2 x 6.1 x 7.0 m(3). It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

sted, utgiver, år, opplag, sider
IOP Publishing , 2020. Vol. 15, nr 12, artikkel-id P12004
Emneord [en]
Large detector systems for particle and astroparticle physics, Noble liquid detectors (scintillation, ionization, double-phase), Time projection Chambers (TPC)
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-350219DOI: 10.1088/1748-0221/15/12/P12004ISI: 000595944800004Scopus ID: 2-s2.0-85097651172OAI: oai:DiVA.org:kth-350219DiVA, id: diva2:1883039
Merknad

QC 20240708

Tilgjengelig fra: 2024-07-08 Laget: 2024-07-08 Sist oppdatert: 2024-07-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Choubey, Sandhya

Søk i DiVA

Av forfatter/redaktør
Choubey, Sandhya
I samme tidsskrift
Journal of Instrumentation

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 26 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf