Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparative Evaluation of Converter Control Impact on Torsional Dynamics of Type-IV Grid-Forming Wind Turbines
Aalborg Univ, DNV R&D Energy Syst, DK-9220 Aalborg, Denmark.;Aalborg Univ, Dept Energy AAU Energy, DK-9220 Aalborg, Denmark..
Aalborg Univ, Comp Sci Dept, DK-9220 Aalborg, Denmark..
Aalborg Univ, Dept Energy, AAU Energy, DK-9220 Aalborg, Denmark..
DNV R&D Energy Syst, NL-6812 AR Arnhem, Netherlands..
Vise andre og tillknytning
2024 (engelsk)Inngår i: IEEE Transactions on Sustainable Energy, ISSN 1949-3029, E-ISSN 1949-3037, Vol. 15, nr 4, s. 2803-2814Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This paper explores the impact of back-to-back converter control strategies on the torsional dynamics of grid-forming permanent magnet synchronous generator wind turbines (GFM-WTs). Two general converter control methods for GFM-WTs, distinguished by the placement of dc-link voltage control (DVC)-either in the machine-side converter or the grid-side converter, are evaluated through the complex torque coefficient method to offer a theoretical basis. It reveals that a negative damping is introduced when the DVC is with the machine-side converter. Then, to further characterize the parametric impacts of electrical and mechanical system constants and controller gains, the sensitivity analysis is performed by employing the partial derivative algorithm, which is based on the feedforward neural network training. It is found that the converter control has a limited impact on the damped frequency in both GFM converter control methods. Finally, electromagnetic simulations based on full-order nonlinear models of GFM-WTs are carried out to confirm the theoretical findings.

sted, utgiver, år, opplag, sider
Institute of Electrical and Electronics Engineers (IEEE) , 2024. Vol. 15, nr 4, s. 2803-2814
Emneord [en]
Voltage control, Wind turbines, Grid forming, Torque, Permanent magnets, Frequency control, Vibrations, Power grids, Synchronous generators, Feedforward neural networks, Grid-forming, permanent magnet synchronous generator, torsional dynamics, feedforward neural network
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-355153DOI: 10.1109/TSTE.2024.3444474ISI: 001328315300040Scopus ID: 2-s2.0-85202751034OAI: oai:DiVA.org:kth-355153DiVA, id: diva2:1907986
Merknad

QC 20241024

Tilgjengelig fra: 2024-10-24 Laget: 2024-10-24 Sist oppdatert: 2024-10-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Wang, Xiongfei

Søk i DiVA

Av forfatter/redaktør
Wang, Xiongfei
Av organisasjonen
I samme tidsskrift
IEEE Transactions on Sustainable Energy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 69 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf