Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Visual simulation of intraocular lenses: technologies and applications [Invited]
Univ Rochester, Flaum Eye Inst, Ctr Visual Sci, Inst Opt, Rochester, NY 14624 USA.
Univ Murcia, Lab Opt, Murcia, Spain.
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Bio-Opto-Nanofysik.ORCID-id: 0000-0002-4894-7944
Univ Houston, Coll Optometry, Houston, TX USA.
2025 (engelsk)Inngår i: Biomedical Optics Express, E-ISSN 2156-7085, Vol. 16, nr 3, s. 1025-1042Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Cataract surgery requires selecting an intraocular lens (IOL), whose design affects visual outcomes. Traditional IOL evaluation relies on optical models and bench testing, but these methods fall short in simulating perceptual factors crucial to patient experience. Visual simulators, based on different principles including adaptive optics, temporal multiplexing or physical projection of the IOLs, now allow patients and clinicians to preview and compare different IOL designs preoperatively. By simulating real-world interactions of the eye's optics and the visual system with IOLs, these simulators enhance the patient decision-making process, enable personalized cataract surgery, and can aid in regulatory assessments of IOLs by incorporating preoperative patient-reported visual outcomes. Visual simulators incorporate deformable mirrors, spatial light modulators and optotunable lenses as dynamic elements to simulate monofocal, multifocal and extended depth-of-focus IOLs, including newer designs aimed at improving contrast sensitivity, expanding depth of focus, and minimizing visual disturbances. With ongoing advancements, these simulators hold potential for transforming IOL design, regulatory processes, and patient care by providing realistic and patient-centered visual assessments, ultimately leading to more successful, individualized surgical outcomes.

sted, utgiver, år, opplag, sider
Optica Publishing Group , 2025. Vol. 16, nr 3, s. 1025-1042
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-361290DOI: 10.1364/BOE.546971ISI: 001434111600003Scopus ID: 2-s2.0-86000338370OAI: oai:DiVA.org:kth-361290DiVA, id: diva2:1944895
Merknad

QC 20250317

Tilgjengelig fra: 2025-03-17 Laget: 2025-03-17 Sist oppdatert: 2025-03-19bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Lundström, Linda

Søk i DiVA

Av forfatter/redaktør
Lundström, Linda
Av organisasjonen
I samme tidsskrift
Biomedical Optics Express

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 54 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf