Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
High Voltage Circuit Breaker Health Index Evaluation Considering Measurement Accuracy
Tallinn University of Technology, Department of Electrical Power Engineering and Mechatronics, Tallinn, Estonia.
Tallinn University of Technology, Department of Electrical Power Engineering and Mechatronics, Tallinn, Estonia.
KTH, Skolan för elektroteknik och datavetenskap (EECS), Elektroteknik, Elektromagnetism och fusionsfysik.ORCID-id: 0000-0003-2025-5759
KTH, Skolan för elektroteknik och datavetenskap (EECS), Elektroteknik, Elektromagnetism och fusionsfysik.ORCID-id: 0000-0002-2964-7233
Vise andre og tillknytning
2024 (engelsk)Inngår i: IEEE PES Innovative Smart Grid Technologies Europe, ISGT EUROPE 2024, Institute of Electrical and Electronics Engineers (IEEE) , 2024Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

The reliable operation of high voltage circuit breakers (HVCBs) is crucial for ensuring the security of the power system. Therefore, the accurate calculation of the health index (HI) for proper maintenance of HVCBs is essential. However, existing methods often neglect two key challenges: proper signal preprocessing for feature extraction and incorporating measurement accuracy into the HI model. This paper addresses these shortcomings by proposing a methodology for improving HI representation for HVCBs. We account for measurement accuracy by considering the varying precision of different monitoring schemes. Furthermore, the impact of signal preprocessing on the condition monitoring data is analyzed. Finally, a case study exhibits how the HI based failure rate can affect the reliability centered maintenance scheduling in the power system.

sted, utgiver, år, opplag, sider
Institute of Electrical and Electronics Engineers (IEEE) , 2024.
Emneord [en]
Circuit breaker, Condition monitoring, Health index, Measurement accuracy, Reliability
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-361448DOI: 10.1109/ISGTEUROPE62998.2024.10863019ISI: 001451133800017Scopus ID: 2-s2.0-86000021141OAI: oai:DiVA.org:kth-361448DiVA, id: diva2:1945878
Konferanse
2024 IEEE PES Innovative Smart Grid Technologies Europe Conference, ISGT EUROPE 2024, Dubrovnik, Croatia, October 14-17, 2024
Merknad

Part of ISBN 9798350390421

QC 20250325

Tilgjengelig fra: 2025-03-19 Laget: 2025-03-19 Sist oppdatert: 2025-08-15bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Shayesteh, EbrahimHilber, Patrik

Søk i DiVA

Av forfatter/redaktør
Shayesteh, EbrahimHilber, Patrik
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 259 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf