Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Leakage identification and correlation coefficient method for industrial workshop production process combining with computational fluid dynamics
KTH, Skolan för arkitektur och samhällsbyggnad (ABE), Byggvetenskap, Hållbara byggnader. Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.
KTH, Skolan för arkitektur och samhällsbyggnad (ABE), Byggvetenskap, Hållbara byggnader. Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.ORCID-id: 0000-0003-0619-8567
Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.
KTH, Skolan för arkitektur och samhällsbyggnad (ABE), Byggvetenskap, Hållbara byggnader. Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.ORCID-id: 0000-0003-1285-2334
2025 (engelsk)Inngår i: Indoor + Built Environment, ISSN 1420-326X, E-ISSN 1423-0070, Vol. 34, nr 1, s. 192-209Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Identifying leakage sources in industrial factory production is crucial to improving air quality, ensuring people’s health and safety and preventing safety accidents. In this study, a method for leakage source identification in industrial factories combining with computational fluid dynamics (CFD) and correlation coefficient was proposed and validated. The study first experimentally validated the numerical methods, which were fundamental to the leakage identification method. Then impacts of leakage sources, sensor errors and number of sensors on the source identification results were evaluated. The results showed that the identification accuracy could be significantly improved by refining the step size of the coefficient ar in this method. When the number of leakage sources was unknown, the accuracy of this method in identifying the number and location of leakages was 93.5%. The computation time spent on source identification depended on the maximum number of leakage sources. Using four sensors with errors were enough to identify the number of unknown leakage sources. The number of leakage sources did not exceed three at the same time. Overall, coupled CFD and correlation coefficients method could effectively identify the number, location and intensity of leakages.

sted, utgiver, år, opplag, sider
SAGE Publications , 2025. Vol. 34, nr 1, s. 192-209
Emneord [en]
Industrial production process, Leakage identification, Source intensity, Source location, Unknown number of sources
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-361779DOI: 10.1177/1420326X241280517ISI: 001313228900001Scopus ID: 2-s2.0-86000756318OAI: oai:DiVA.org:kth-361779DiVA, id: diva2:1948046
Merknad

QC 20250401

Tilgjengelig fra: 2025-03-27 Laget: 2025-03-27 Sist oppdatert: 2025-04-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Wang, YukunLiu, YuefeiLiu, Wei

Søk i DiVA

Av forfatter/redaktør
Wang, YukunLiu, YuefeiLiu, Wei
Av organisasjonen
I samme tidsskrift
Indoor + Built Environment

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 51 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf