Investigation of heat recovery in CO2 refrigeration cycles for supermarkets: A mechanism for determining optimal discharge pressure
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik.ORCID-id: 0000-0002-5543-6528
2025 (engelsk)Inngår i: Applied Thermal Engineering, ISSN 1359-4311, E-ISSN 1873-5606, Vol. 274, artikkel-id 126728Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The benefit of two-stage heat recovery compared to one-stage heat recovery is not deeply investigated in CO2 refrigeration systems with heat recovery in supermarkets. Moreover, the optimum discharge pressure respecting the thermodynamic principles governing the heat recovery heat exchangers, has not been defined. This study addresses this research gap combining existing knowledge of the pinch point in CO2 heat pump gas coolers and supermarket refrigeration systems with heat recovery. This novel approach leads to more accurate control and design inputs for the commercial refrigeration industry. Key findings of the study in a Swedish supermarket show that two-stage heat recovery, compared to one-stage, improves the Seasonal Performance Factor for heat (SPF) by 17 %, with the refrigeration cycle's annual energy savings reaching up to 4 % in cold climates. Additionally, heat export capabilities to district heating networks are explored, demonstrating a 25 % efficiency improvement with a two-stage configuration instead of a one-stage configuration. Moreover, increasing the discharge pressure by less than 5 bar compared to the optimum value can reduce the total required UA-value of the heat recovery heat exchangers by 45–48 %, with a maximum SPF penalty of 2.8 %

sted, utgiver, år, opplag, sider
Elsevier BV , 2025. Vol. 274, artikkel-id 126728
Emneord [en]
Carbon dioxide (CO ) 2, Heat recovery, Modelling, Refrigeration, Supermarket
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-363408DOI: 10.1016/j.applthermaleng.2025.126728ISI: 001509273000001Scopus ID: 2-s2.0-105004369101OAI: oai:DiVA.org:kth-363408DiVA, id: diva2:1958503
Merknad

QC 20250516

Tilgjengelig fra: 2025-05-15 Laget: 2025-05-15 Sist oppdatert: 2025-08-15bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Thanasoulas, Sotirios

Søk i DiVA

Av forfatter/redaktør
Thanasoulas, Sotirios
Av organisasjonen
I samme tidsskrift
Applied Thermal Engineering

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 135 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf