Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Green Fabrication of Sulfonium-Containing Bismuth Materials for High-Sensitivity X-Ray Detection
Department Solution-Processing of Hybrid Materials and Devices, Helmholtz-Zentrum Berlin, 14109 Berlin, Germany.
Department of Materials Chemistry, Federal Institute for Materials Research and Testing, 12205 Berlin, Germany.
Freigeist Juniorgroup, Radiation Tolerant Electronics with Soft Semiconductors (ROSI), University of Potsdam, 14476 Potsdam-Golm, Germany.
Soft Matter Physics and Optoelectronics Group, University of Potsdam, 14476 Potsdam-Golm, Germany.
Vise andre og tillknytning
2025 (engelsk)Inngår i: Advanced Materials, ISSN 0935-9648, E-ISSN 1521-4095, Vol. 37, nr 24, artikkel-id 2418626Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Organic-inorganic hybrid materials based on lead and bismuth have recently been proposed as novel X- and gamma-ray detectors for medical imaging, non-destructive testing, and security, due to their high atomic numbers and facile preparation compared to traditional materials like amorphous selenium and Cd(Zn)Te. However, challenges related to device operation, excessively high dark currents, and long-term stability have delayed commercialization. Here, two novel semiconductors incorporating stable sulfonium cations are presented, [(CH3CH2)3S]6Bi8I30 and [(CH3CH2)3S]AgBiI5, synthesized via solvent-free ball milling and fabricated into dense polycrystalline pellets using cold isostatic compression, two techniques that can easily be upscaled, for X-ray detection application. The fabricated detectors exhibit exceptional sensitivities (14 100-15 190 mu C Gyair-1 cm-2) and low detection limits (90 nGyair s-1 for [(CH3CH2)3S]6Bi8I30 and 78 nGyair s-1 for [(CH3CH2)3S]AgBiI5), far surpassing current commercial detectors. Notably, they maintain performance after 9 months of ambient storage. The findings highlight [(CH3CH2)3S]6Bi8I30 and [(CH3CH2)3S]AgBiI5 as scalable, cost-effective and highly stable alternatives to traditional semiconductor materials, offering great potential as X-ray detectors in medical and security applications.

sted, utgiver, år, opplag, sider
Wiley , 2025. Vol. 37, nr 24, artikkel-id 2418626
Emneord [en]
compressed pellets, heterometallic iodobismuthate, long-term stability, mechanosynthesis, new materials, sulfonium iodobismuthate, X-ray detectors
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-363556DOI: 10.1002/adma.202418626ISI: 001462697300001PubMedID: 40207598Scopus ID: 2-s2.0-105002328812OAI: oai:DiVA.org:kth-363556DiVA, id: diva2:1959075
Merknad

QC 20260126

Tilgjengelig fra: 2025-05-19 Laget: 2025-05-19 Sist oppdatert: 2026-01-26bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Kloo, LarsSvensson, Per H.

Søk i DiVA

Av forfatter/redaktør
Kloo, LarsSvensson, Per H.Maslyanchuk, Olena
Av organisasjonen
I samme tidsskrift
Advanced Materials

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 99 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf