Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
On-chip colorimetric assay for determining serum lithium concentration from whole blood
KTH, Skolan för elektroteknik och datavetenskap (EECS), Intelligenta system, Mikro- och nanosystemteknik.
KTH, Skolan för elektroteknik och datavetenskap (EECS), Intelligenta system, Mikro- och nanosystemteknik.ORCID-id: 0000-0003-3601-0342
KTH, Skolan för elektroteknik och datavetenskap (EECS), Intelligenta system, Mikro- och nanosystemteknik.ORCID-id: 0000-0002-3549-0228
Karolinska Inst, Dept Mol Med & Surg, Stockholm, Sweden; Stockholm Healthcare Serv, Psychiat Southwest, Stockholm, Sweden; Karolinska Univ Hosp, Ctr Mol Med, Stockholm, Sweden.
Vise andre og tillknytning
2025 (engelsk)Inngår i: Lab on a Chip, ISSN 1473-0197, E-ISSN 1473-0189, Vol. 25, nr 9, s. 2270-2277Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Lithium is the first-line treatment for bipolar disorder. However, the narrow therapeutic window of serum (s-)lithium is near its toxicity range, necessitating continuous monitoring of patients, a process involving regular hospital visits. On-demand home sampling could allow for more frequent testing, possibly resulting in safer patient outcomes, further dosage optimization, and increased compliance. This article presents a device that measures the s-lithium concentration from whole blood. The device consists of a single-use cartridge able to conduct on-chip serum filtration, volume-metering and an on-chip colorimetric assay. Spiked whole blood shows good linearity (Pearson's r = 0.96, R2 = 0.92), a limit-of-detection of 0.3 mmol L-1, and an average deviation of 0.05 mmol L-1 (+/- 6%) compared to atomic absorption spectroscopy. The on-chip colorimetric assay has shown to be a promising technique for measuring s-lithium concentration from whole blood and could allow patients to assess lithium levels at home and make the treatment available for new patient groups.

sted, utgiver, år, opplag, sider
Royal Society of Chemistry (RSC) , 2025. Vol. 25, nr 9, s. 2270-2277
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-363628DOI: 10.1039/d5lc00044kISI: 001461913000001PubMedID: 40202101Scopus ID: 2-s2.0-105002381292OAI: oai:DiVA.org:kth-363628DiVA, id: diva2:1959383
Merknad

QC 20250520

Tilgjengelig fra: 2025-05-20 Laget: 2025-05-20 Sist oppdatert: 2025-05-20bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Olsson, CarlHauser, JanoschRibet, FedericoRoxhed, Niclas

Søk i DiVA

Av forfatter/redaktør
Olsson, CarlHauser, JanoschRibet, FedericoRoxhed, Niclas
Av organisasjonen
I samme tidsskrift
Lab on a Chip

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 66 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf