Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Monitoring Acetone with Photoacoustic Spectroscopy Using a Metal–Organic Framework
Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, P. R. China; Taizhou Hospital, Zhejiang University, Taizhou, 318000, P. R. China.
Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, P. R. China.
Taizhou Hospital, Zhejiang University, Taizhou, 318000, P. R. China.
Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, P. R. China.
Vise andre og tillknytning
2024 (engelsk)Inngår i: Advanced Optical Materials, ISSN 2162-7568, E-ISSN 2195-1071, Vol. 12, nr 10, artikkel-id 2302280Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Herein, this study describes a sample preconcentration apparatus based on a metal–organic framework (MOF) of NH2-UIO-66@PDMS adsorbent, which is first coupled to photoacoustic spectroscopy (PAS) technology for detection of acetone. The MOF selectively traps acetone out of complex samples and releases it into the photoacoustic (PA) cell, where PA signal intensity is recorded by PAS sensing system based on a cheap amplitude modulated UV LED as light source. The signal intensity is enhanced by 11 times after preconcentration of NH2-UIO-66@PDMS (100 mg). The preconcentration apparatus not only enhances sensitivity of sensor, but also promotes the anti-interference ability for common interferents (carbon dioxide, oxygen and water vapor, ethanol, propanol, etc.) of the sensor. As expected, the established PA sensor possesses a detection limit of 0.23 ppm for measuring acetone, which can feasibly be applied for the analysis of acetone in patients breath samples. This work provides a good example of the preconcentration effect of MOF for promoting PA sensor analytical performance, and the prospect of medical diagnosis.

sted, utgiver, år, opplag, sider
Wiley , 2024. Vol. 12, nr 10, artikkel-id 2302280
Emneord [en]
acetone, NH2-UIO-66@PDMS, photoacoustic sensor, preconcentration, UV LED
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-367017DOI: 10.1002/adom.202302280ISI: 001153384400001Scopus ID: 2-s2.0-85183620754OAI: oai:DiVA.org:kth-367017DiVA, id: diva2:1983951
Merknad

QC 20250714

Tilgjengelig fra: 2025-07-14 Laget: 2025-07-14 Sist oppdatert: 2025-07-14bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

He, Sailing

Søk i DiVA

Av forfatter/redaktør
He, Sailing
Av organisasjonen
I samme tidsskrift
Advanced Optical Materials

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 31 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf