Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Demonstrating the Analytical Potential of a Wearable Microneedle-Based Device for Intradermal CO2 Detection
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Kemi, Tillämpad fysikalisk kemi. UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain.
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Kemi, Tillämpad fysikalisk kemi.ORCID-id: 0000-0002-6128-5340
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Kemi, Tillämpad fysikalisk kemi. UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain.ORCID-id: 0000-0002-4648-1861
Section of Neuropharmacology and Addiction Research, Department of Pharmaceutical Biosciences, Uppsala University, Uppsala 753 10, Sweden.
Vise andre og tillknytning
2024 (engelsk)Inngår i: ACS Sensors, E-ISSN 2379-3694, Vol. 9, nr 1, s. 361-370Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Monitoring of carbon dioxide (CO2) body levels is crucial under several clinical conditions (e.g., human intensive care and acid–base disorders). To date, painful and risky arterial blood punctures have been performed to obtain discrete CO2 measurements needed in clinical setups. Although noninvasive alternatives have been proposed to assess CO2, these are currently limited to benchtop devices, requiring trained personnel, being tedious, and providing punctual information, among other disadvantages. To the best of our knowledge, the literature and market lack a wearable device for real-time, on-body monitoring of CO2. Accordingly, we have developed a microneedle (MN)-based sensor array, labeled as CO2–MN, comprising a combination of potentiometric pH- and carbonate (CO32–)-selective electrodes together with the reference electrode. The CO2–MN is built on an epidermal patch that allows it to reach the stratum corneum of the skin, measuring pH and CO32– concentrations directly into the interstitial fluid (ISF). The levels for the pH–CO32– tandem are then used to estimate the PCO2 in the ISF. Assessing the response of each individual MN, we found adequate response time (t95 < 5s), sensitivity (50.4 and −24.6 mV dec–1 for pH and CO32–, respectively), and stability (1.6 mV h–1 for pH and 2.1 mV h–1 for CO32–). We validated the intradermal measurements of CO2 at the ex vivo level, using pieces of rat skin, and then, with in vivo assays in anesthetized rats, showing the suitability of the CO2–MN wearable device for on-body measurements. A good correlation between ISF and blood CO2 concentrations was observed, demonstrating the high potential of the developed MN sensing technology as an alternative to blood-based analysis in the near future. Moreover, these results open new horizons in the noninvasive, real-time monitoring of CO2 as well as other clinically relevant gases. 

sted, utgiver, år, opplag, sider
American Chemical Society (ACS) , 2024. Vol. 9, nr 1, s. 361-370
Emneord [en]
blood correlation, CO2 sensing, in vivo measurements, interstitial fluid, ion-selective microneedles, wearable sensor
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-367150DOI: 10.1021/acssensors.3c02086ISI: 001152678300001PubMedID: 38175931Scopus ID: 2-s2.0-85182013919OAI: oai:DiVA.org:kth-367150DiVA, id: diva2:1984224
Merknad

QC 20250715

Tilgjengelig fra: 2025-07-15 Laget: 2025-07-15 Sist oppdatert: 2025-07-15bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Molinero-Fernandez, AguedaWang, QianyuXuan, XingCrespo, Gaston A.Cuartero, Maria

Søk i DiVA

Av forfatter/redaktør
Molinero-Fernandez, AguedaWang, QianyuXuan, XingCrespo, Gaston A.Cuartero, Maria
Av organisasjonen
I samme tidsskrift
ACS Sensors

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 83 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf