Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Integrated microoptical system for continuous fluorescence monitoring of microtissues
KTH, Skolan för elektroteknik och datavetenskap (EECS), Intelligenta system, Mikro- och nanosystemteknik.ORCID-id: 0009-0007-6016-3708
KTH, Skolan för elektroteknik och datavetenskap (EECS), Intelligenta system, Mikro- och nanosystemteknik.ORCID-id: 0000-0002-9144-0065
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Proteinvetenskap, Nanobioteknologi. KTH, Centra, Science for Life Laboratory, SciLifeLab. (Herland Lab)ORCID-id: 0000-0001-8433-2181
Vise andre og tillknytning
2025 (engelsk)Inngår i: Microsystems & Nanoengineering, E-ISSN 2055-7434, Vol. 11, nr 1, artikkel-id 213Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Microphysiological systems (MPS) are advanced in vitro platforms engineered to replicate in vivo conditions for studying human biology, disease mechanisms, and drug responses with greater physiological relevance. Fluorescence sensing is widely used as a functional readout in MPS due to its high sensitivity, selectivity, and stability. However, conventional fluorescence sensing systems often rely on bulky instrumentation with limited integration, which restricts continuous in situ monitoring, scalable high-throughput analysis, and spatially resolved investigation in multi-organ-on-a-chip models. To address these limitations, we present a highly miniaturized, fully integrated optical system with a 1 mm² footprint, enabling continuous in situ fluorescence monitoring of three-dimensional microtissues in close proximity. The system integrates microscale illumination and sensing units for fluorescence excitation and selective detection, an optical element for guided light propagation, and a microcage for mechanical confinement of microtissues. To demonstrate its capabilities, we integrated the miniaturized optical system with an MPS-relevant platform to monitor fluorescence signals in transgenic mouse pancreatic islets expressing genetically encoded calcium indicators. The integrated platform enables real-time, continuous monitoring of islet responses to potassium chloride stimulation and tracking of calcium oscillations for over two hours, providing valuable information about the functional status of the pancreatic islets. Our work enhances the analytical capabilities of MPS through the integration of miniaturized on-chip quantitative assessment tools, enabling precise, in situ, and continuous monitoring of biological activities in close proximity.

sted, utgiver, år, opplag, sider
Springer Nature , 2025. Vol. 11, nr 1, artikkel-id 213
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-373124DOI: 10.1038/s41378-025-01073-4PubMedID: 41224775Scopus ID: 2-s2.0-105021471430OAI: oai:DiVA.org:kth-373124DiVA, id: diva2:2015070
Merknad

QC 20251121

Tilgjengelig fra: 2025-11-20 Laget: 2025-11-20 Sist oppdatert: 2026-01-23bibliografisk kontrollert
Inngår i avhandling
1. Integrated Microsystems for Fluorescence Sensing and Ultrasonic Energy Harvesting in Biomedical Applications
Åpne denne publikasjonen i ny fane eller vindu >>Integrated Microsystems for Fluorescence Sensing and Ultrasonic Energy Harvesting in Biomedical Applications
2026 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Advances in miniaturized biomedical microsystems, ranging from in vitro microphysiological systems (MPS) to implantable devices, are enabling new modes of continuous, autonomous preclinical studies. This thesis presents a set of interconnected research contributions on millimeter-scale fluorescence-sensing and ultrasonic energy-harvesting microsystems, collectively advancing the development of integrated and miniaturized biomedical instrumentation.

The first part introduces an integrated microoptical system for fluorescence sensing in MPS, incorporating custom micro-optics and miniaturized excitation and detection units with tailored optical filters. This platform enables real-time, continuous fluorescence monitoring of microtissues under physiologically relevant conditions, strengthening the analytical capabilities of MPS for long-duration studies of drug delivery and cellular behavior.

The second part translates these sensing concepts to fully implantable microsystems capable of autonomous, long-term in vivo fluorescence recording. A compact 5 × 5 × 5 mm³ implant integrates a miniaturized optical module and low-power electronics to track fluorescence dynamics within living tissue. Validated across phantom, in vitro, ex vivo, and in vivo studies, the system demonstrates two-week continuous tracking of tumor-associated fluorescence, establishing its suitability for preclinical studies.

The final part focuses on ultrasonic energy harvesting to enable the autonomous operation of implantable devices. A MEMS-based piezoelectric ultrasonic energy harvester (PUEH) fabricated using a low-temperature bonding process allows integration of high-performance bulk PZT-5H, demonstrating the potential of MEMS architectures for efficient ultrasonic power transfer. An integrated energy-harvesting node, also in a 5 × 5 × 5 mm³ form factor, combines the MEMS-based PUEH with power management and storage to support autonomous operation of millimetric implants.

Together, these contributions advance miniaturized fluorescence sensing and ultrasonic energy transfer, enabling versatile microsystems for biomedical applications.

Abstract [sv]

Framsteg inom miniatyriserade biomedicinska mikrosystem, allt från in vitro-mikrofysiologiska system (MPS) till implanterbara enheter, möjliggör nya former av kontinuerliga, autonoma prekliniska studier. Denna avhandling presenterar en uppsättning sammankopplade forskningsbidrag om millimeterskaliga fluorescensavkännande och ultraljudsenergiupptagnings-mikrosystem, som tillsammans främjar utvecklingen av integrerade och miniatyriserade biomedicinska instrument.

Den första delen introducerar ett integrerat mikrooptiskt system för fluorescensavkänning i MPS, som innehåller anpassad mikrooptik och miniatyriserade excitations- och detektionsenheter med skräddarsydda optiska filter. Denna plattform möjliggör kontinuerlig fluorescensövervakning i realtid av mikrovävnader under fysiologiskt relevanta förhållanden, vilket stärker MPS analytiska kapacitet för långvariga studier av läkemedelsleverans och cellulärt beteende. Den andra delen översätter dessa avkänningskoncept till helt implanterbara mikrosystem som kan utföra autonom, långsiktig in vivo-fluorescensregistrering. Ett kompakt 5 × 5 × 5 mm³-implantat integrerar en miniatyriserad optisk modul och lågeffektselektronik för att spåra fluorescensdynamik i levande vävnad. Systemet har validerats i fantom-, in vitro-, ex vivo- och in vivo-studier och demonstrerar två veckors kontinuerlig övervakning av tumörassocierad fluorescens, vilket fastställer dess lämplighet för prekliniska studier. Den sista delen fokuserar på ultraljudsenergiupp-samling för att möjliggöra autonom implantatdrift. En MEMS-baserad piezoelektrisk ultraljudsenergiuppsamlingsenhet (PUEH) tillverkad med en lågtemperaturbindningsprocess möjliggör integration av högpresterande bulk-PZT-5H, vilket demonstrerar potentialen hos MEMS-arkitekturer för effektiv ultraljudsenergiöverföring. En integrerad energiuppsamlingsnod, också i en formfaktor på 5 × 5 × 5 mm³, kombinerar MEMS PUEH med energihantering och lagring för att stödja autonom drift av millimetriska implantat.

Tillsammans främjar dessa bidrag miniatyriserad fluorescensavkänning och ultraljudsenergiöverföring, vilket möjliggör mångsidiga mikrosystem för biomedicinska tillämpningar.

sted, utgiver, år, opplag, sider
Stockholm, Sweden: KTH Royal Institute of Technology, 2026. s. ix, 73
Serie
TRITA-EECS-AVL ; 2026:11
Emneord
Integrated Microsystems, Fluorescence Sensing, Ultrasonic Energy Harvesting, Integrerade mikrosystem, fluorescensavkänning, ultraljudsenergiinsamling
HSV kategori
Forskningsprogram
Elektro- och systemteknik
Identifikatorer
urn:nbn:se:kth:diva-375879 (URN)978-91-8106-517-6 (ISBN)
Disputas
2026-02-20, https://kth-se.zoom.us/j/63767237845, Q2, Room B218, Malvinas väg 10, Stockholm, 13:00 (engelsk)
Opponent
Veileder
Merknad

QC 20260127

Tilgjengelig fra: 2026-01-27 Laget: 2026-01-23 Sist oppdatert: 2026-02-09bibliografisk kontrollert

Open Access i DiVA

fulltext(2403 kB)43 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2403 kBChecksum SHA-512
fd8a92e85e9601c924607815c6a4e3471abd5dad75e489814487c24e792123439686bc65782f853ff290b3d444696704d94d86c67489cdd2459e8a933dacbdd7
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Tian, XuKavand, HanieJessika, JessikaStemme, Göranvan der Wijngaart, WouterHerland, AnnaRoxhed, Niclas

Søk i DiVA

Av forfatter/redaktør
Tian, XuKavand, HanieKöhler, MartinJessika, JessikaBerggren, Per-OlofStemme, Göranvan der Wijngaart, WouterHerland, AnnaRoxhed, Niclas
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 435 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf