Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Investigation of data-driven stopping power calibration of treatment planning x-ray CT from simulated sparse-view proton radiographies
Ludwig Maximilians Univ Munchen, Chair Med Phys, Munich, Germany.
Tech Univ Munich, Sch Computat Informat & Technol, Munich, Germany.
Sapienza Univ Rome, Dept Basic & Appl Sci Engn, Rome, Italy.
Sapienza Univ Rome, Dept Basic & Appl Sci Engn, Rome, Italy.
Vise andre og tillknytning
2025 (engelsk)Inngår i: Physics in Medicine and Biology, ISSN 0031-9155, E-ISSN 1361-6560, Vol. 70, nr 24, artikkel-id 245007Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Objective. Proton therapy treatment planning currently needs to account for relatively large range uncertainty margins primarily due to the semi-empirical calibration of the treatment planning x-ray computed tomography (CT) to proton stopping power relative to water (RSP). Proton radiography enables direct measurement of integral RSP, offering potential to improve calibration and reduce these uncertainties. Approach. Three deep neural network architectures are trained to infer a patient RSP map using the treatment planning CT and proton radiographies, assuming straight proton trajectories. The best suited architecture is then evaluated on more realistic, clinical-like data generated with Monte Carlo simulations. Three idealized proton imaging detectors are simulated: single particle tracking (SPT), a pixelated energy-resolving imager (PERI) and a proton-integrating detector (PID). Main results. The learned primal dual (LPD) architetcure performs best in the simplified imaging scenario. In the more realistic scenario, the initial calibration error (median absolute percentage error of 2.24% across the test set) is reduced using only two projections across all detector types. SPT and PERI reach similar performance (1.10%/1.12%), followed by PID (1.30%). Restricting the LPD to the calibration task by incorporating prior knowledge of the functional relationship of Hounsfield Units (HUs) and RSP further improves calibration performance. For SPT, conventional optimization on detector data acquired for individual protons outperformed the data-driven method (0.16% vs. 1.10%). However, for PERI and PID, the data-driven approach (1.12%/1.30%) slightly outperformed conventional optimization (1.63%/1.72%). Significance. To our knowledge, this is the first study to apply a deep learning-based approach fusing proton radiographies and treatment planning CT data for improved RSP calibration. The method achieves lower calibration errors than idealized, conventional calibration curve optimization on PERIs and PIDs-detector types that offer a promising path for clinical adoption due to their lower complexity and cost compared to SPT systems.

sted, utgiver, år, opplag, sider
IOP Publishing , 2025. Vol. 70, nr 24, artikkel-id 245007
Emneord [en]
proton imaging, proton radiography, patient-specific stopping power calibration, deep image processing, deep image fusion, deep image reconstruction
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-377204DOI: 10.1088/1361-6560/ae2418ISI: 001636300600001PubMedID: 41289688Scopus ID: 2-s2.0-105024727012OAI: oai:DiVA.org:kth-377204DiVA, id: diva2:2041326
Merknad

QC 20260224

Tilgjengelig fra: 2026-02-24 Laget: 2026-02-24 Sist oppdatert: 2026-02-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Öktem, Ozan

Søk i DiVA

Av forfatter/redaktør
Öktem, Ozan
Av organisasjonen
I samme tidsskrift
Physics in Medicine and Biology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 43 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf