Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Detection of Thrombi in Extracorporeal Membrane Oxygenation Circuits Using Low-Frequency Acoustic Measurements
KTH, Skolan för teknikvetenskap (SCI), Teknisk mekanik, Strömningsmekanik. (FLOW)ORCID-id: 0009-0003-9375-1806
Department of Anaesthesia, Surgery and Intensive Care, Sundsvall Hospital, Region Västernorrland, Sundsvall, Sweden; Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, Sweden.
Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, Sweden; ECMO Centre Karolinska, Pediatric Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden.
KTH, Skolan för teknikvetenskap (SCI), Teknisk mekanik, Strömningsmekanik. (FLOW)ORCID-id: 0000-0001-9976-8316
Vise andre og tillknytning
2025 (engelsk)Inngår i: ASAIO journal (1992), ISSN 1058-2916, E-ISSN 1538-943XArtikkel i tidsskrift (Fagfellevurdert) Epub ahead of print
Abstract [en]

Extracorporeal membrane oxygenation (ECMO) provides temporary support for patients with severe acute cardiac or respiratory failure. Although thrombotic complications are common during ECMO, the real-time detection and management of thrombosis-related complications remain challenging. In this study, we introduce a noninvasive approach for detecting thrombi using an acoustic detection technique. The presence of blood clots in the ECMO circuit has been correlated with an increase in the amplitude of the acoustic spectrum <20 Hz. This amplification allows for the prediction of clots in the ECMO circuit using acoustic measurements. The predicted results were compared with visual observations, and the technique achieved a total accuracy of 84%. Hypothesizing that some of the false positives were indicators of clots in the circuitry, the accuracy may be up to 96%. This technique could be integrated with the existing clot detection method to enhance patient outcomes.

sted, utgiver, år, opplag, sider
Ovid Technologies (Wolters Kluwer Health) , 2025.
Emneord [en]
infra-sound, thrombi
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-377331DOI: 10.1097/MAT.0000000000002661PubMedID: 41664281Scopus ID: 2-s2.0-105029721625OAI: oai:DiVA.org:kth-377331DiVA, id: diva2:2041900
Merknad

QC 20260226

Tilgjengelig fra: 2026-02-26 Laget: 2026-02-26 Sist oppdatert: 2026-02-26bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Nanayakkara, SheranPrahl Wittberg, Lisa

Søk i DiVA

Av forfatter/redaktør
Nanayakkara, SheranPrahl Wittberg, Lisa
Av organisasjonen
I samme tidsskrift
ASAIO journal (1992)

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 41 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf