Numerically generated g-functions for ground coupled heat pump applications
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik.ORCID-id: 0000-0002-3490-1777
University of Genova.
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik.ORCID-id: 0000-0002-5093-9070
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik.ORCID-id: 0000-0002-9902-2087
2012 (engelsk)Inngår i: Proceedings of the COMSOL Conference in Milan, 2012Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

In most ground-coupled heat pump systems, Borehole Heat Exchangers (BHE) represent the typical engineering solution for utilizing renewable energy from the ground. The design of a complex BHE field is a challenging task, due the inherent transient nature of the thermal interaction between the heat exchangers and the surrounding soil. A computation effective method for solving the 3D transient conduction equation describing the ground response to a variable heat load profile is the temporal superposition of pre-calculated temperature response factors or g-functions. In this study Comsol heat conduction models have been developed to calculate g-function values for a borehole field with 64 boreholes. The aim of the investigation is to get an insight on the numerical generation of temperature transfer functions and to some extent provide new information on the Finite Line Source method for analytically generated g-functions as well as on those existing behind existing design software such as EED. The results generally showed a good agreement in lower time ranges. Further in time, the Comsol model revealed to be influenced either by the domain dimensions or the simulation end time.

sted, utgiver, år, opplag, sider
2012.
Emneord [en]
g-function, borehole heat exchanger, long term performance, FLS, EED, numerical, ground coupled heat pumps
HSV kategori
Forskningsprogram
Energiteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-131440OAI: oai:DiVA.org:kth-131440DiVA, id: diva2:921635
Konferanse
2012 COMSOL Conference, Webinar,Boston, Milan, Bangalore, Beijing, Seoul, Shanghai, Taipei, and Tokyo, 2012
Merknad

QC 20160429

Tilgjengelig fra: 2016-04-20 Laget: 2013-10-15 Sist oppdatert: 2022-06-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Conference website

Person

Acuna, JoséMonzó, PatriciaPalm, Björn

Søk i DiVA

Av forfatter/redaktør
Acuna, JoséMonzó, PatriciaPalm, Björn
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 1611 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf