A novel solar thermal polygeneration system for sustainable production of cooling, clean water and domestic hot water in United Arab Emirates: Dynamic simulation and economic evaluation
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Kraft- och värmeteknologi.ORCID-id: 0000-0002-3661-7016
2016 (engelsk)Inngår i: Applied Energy, ISSN 0306-2619, E-ISSN 1872-9118, Vol. 167, s. 173-188Artikkel i tidsskrift (Fagfellevurdert) Published
Resurstyp
Text
Abstract [en]

In this paper, a novel solar thermal polygeneration (STP) system for production of cooling, clean water and domestic hot water is modeled and analyzed for the weather conditions of United Arab Emirates (UAE). The system comprises of solar collectors for production of thermal energy, single stage LiBr-H2O absorption chiller (VAC) for providing air conditioning to office cabins and membrane distillation (MD) modules for clean water production along with domestic hot water generation as by-product. The performance of STP is analyzed with three different solar collectors - flat plate collectors (FPC), evacuated tube collector (ETC) and compound parabolic collector (CPC). The system is modeled and dynamically simulated using TRNSYS software for optimization of various design parameters like slope of the collectors, mass flow rate through the collector loop, storage capacity and area of collectors. Combined and system efficiency of the STP system has been determined for optimum conditions. Economic benefits are analyzed for different collectors and fuel costs savings. A lowest payback period of 6.75 years is achieved by STP with evacuated tube collector field having gross area of 216 m2. STP system has cumulative savings of $520,000 over the life time of the project through roof top solar collector installation. In terms of environmental benefits, 109 metric tons/year of CO2 emissions would be avoided and hence the overall payback period would be reduced by 8% based on cost saving through carbon credits. Economic and environmental benefits were aided by steady system performances of absorption chiller (35 kW), membrane distiller (80 l/day) and heat recovery system (1.2 m3/h) throughout the year. The complete simulation results of the STP system is utilized for the development, installation and testing of a polygeneration system at RAKRIC.

sted, utgiver, år, opplag, sider
Elsevier, 2016. Vol. 167, s. 173-188
Emneord [en]
Absorption chiller, Membrane distillation, Polygeneration, Solar thermal, TRNSYS, UAE
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-187199DOI: 10.1016/j.apenergy.2015.10.116ISI: 000373748400014Scopus ID: 2-s2.0-84977904182OAI: oai:DiVA.org:kth-187199DiVA, id: diva2:929584
Forskningsfinansiär
StandUp
Merknad

QC 20160519

Tilgjengelig fra: 2016-05-19 Laget: 2016-05-18 Sist oppdatert: 2026-05-29bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Martin, Andrew

Søk i DiVA

Av forfatter/redaktør
Martin, Andrew
Av organisasjonen
I samme tidsskrift
Applied Energy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 382 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf