Experimental study of the pressure reset control strategy for energy-efficient fan operation: Part 1: Variable air volume ventilation system with dampers
KTH, Skolan för arkitektur och samhällsbyggnad (ABE), Byggvetenskap, Strömnings- och klimatteknik. Aalborg University, Denmark.ORCID-id: 0000-0002-9361-1796
2017 (Engelska)Ingår i: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 139, s. 72-77Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

This paper is the first part of a two-part series which investigate the energy saving potentials in a novel mechanical ventilation system by replacing terminal dampers with decentralized fans. In Part 1, a conventional variable air volume (VAV) ventilation system with dampers is studied as a reference for comparison with the novel ventilation system in Part 2. The present study (Part 1) proposes a new method to implement the pressure reset strategy in practice. A common strategy to control the supply fan speed in a VAV system is to install a pressure sensor in the supply duct system. Then the fan speed is controlled such that a constant static pressure is maintained at the sensor location. Further energy saving can be obtained by resetting the pressure setpoint to a lower value at partial load conditions. This strategy is known as pressure reset control or critical zone reset strategy in the literature. The proposed method has been evaluated through an experimental mock-up in a laboratory environment. Experimental results show a minimum reduction of about 20% in fan power demand with applying the reset strategy compared to a constant static pressure setpoint.

Ort, förlag, år, upplaga, sidor
Elsevier, 2017. Vol. 139, s. 72-77
Nyckelord [en]
Critical zone reset, Energy efficient control, Pressure reset, VAV ventilation system
Nationell ämneskategori
Energiteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-200868DOI: 10.1016/j.enbuild.2016.12.080ISI: 000395599200008Scopus ID: 2-s2.0-85008870028OAI: oai:DiVA.org:kth-200868DiVA, id: diva2:1072070
Anmärkning

QC 20170207

Tillgänglig från: 2017-02-07 Skapad: 2017-02-03 Senast uppdaterad: 2024-03-18Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Sadrizadeh, Sasan

Sök vidare i DiVA

Av författaren/redaktören
Sadrizadeh, Sasan
Av organisationen
Strömnings- och klimatteknik
I samma tidskrift
Energy and Buildings
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 222 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf