Temperature-controlled airflow ventilation in operating rooms compared with laminar airflow and turbulent mixed airflow
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: Journal of Hospital Infection, ISSN 0195-6701, E-ISSN 1532-2939, Vol. 98, nr 2, s. 181-190Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Aim: To evaluate three types of ventilation systems for operating rooms with respect to air cleanliness [in colony-forming units (cfu/m(3))], energy consumption and comfort of working environment (noise and draught) as reported by surgical team members. Methods: Two commonly used ventilation systems, vertical laminar airflow (LAF) and turbulent mixed airflow (TMA), were compared with a newly developed ventilation technique, temperature-controlled airflow (T(c)AF). The cfu concentrations were measured at three locations in an operating room during 45 orthopaedic procedures: close to the wound (<40 cm), at the instrument table and peripherally in the room. The operating team evaluated the comfort of the working environment by answering a questionnaire. Findings: LAF and T(c)AF, but not TMA, resulted in less than 10 cfu/m(3) at all measurement locations in the room during surgery. Median values of cfu/m(3) close to the wound (250 samples) were 0 for LAF, 1 for T(c)AF and 10 for TMA. Peripherally in the room, the cfu concentrations were lowest for T(c)AF. The cfu concentrations did not scale proportionally with airflow rates. Compared with LAF, the power consumption of T(c)AF was 28% lower and there was significantly less disturbance from noise and draught. Conclusion: T(c)AF and LAF remove bacteria more efficiently from the air than TMA, especially close to the wound and at the instrument table. Like LAF, the new T(c)AF ventilation system maintained very low levels of cfu in the air, but T(c)AF used substantially less energy and provided a more comfortable working environment than LAF. This enables energy savings with preserved air quality.

Ort, förlag, år, upplaga, sidor
W B SAUNDERS CO LTD , 2018. Vol. 98, nr 2, s. 181-190
Nyckelord [en]
Surgical site infection, BioTrak, Fluorescence, Energy efficiency, Temperature-controlled, ventilation, Air sampling
Nationell ämneskategori
Geovetenskap och relaterad miljövetenskap
Identifikatorer
URN: urn:nbn:se:kth:diva-223799DOI: 10.1016/j.jhin.2017.10.013ISI: 000425104000013PubMedID: 29074054Scopus ID: 2-s2.0-85034808911OAI: oai:DiVA.org:kth-223799DiVA, id: diva2:1188249
Forskningsfinansiär
Forskningsrådet Formas, 2014-1460Energimyndigheten, 2016-004864
Anmärkning

QC 20180307

Tillgänglig från: 2018-03-07 Skapad: 2018-03-07 Senast uppdaterad: 2025-02-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Sadrizadeh, Sasan

Sök vidare i DiVA

Av författaren/redaktören
Sadrizadeh, Sasan
Av organisationen
Strömnings- och klimatteknik
I samma tidskrift
Journal of Hospital Infection
Geovetenskap och relaterad miljövetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 752 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf