kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Persistence Length of Poly(vinyl amine): Quantitative Image Analysis versus Single Molecule Force Response
Univ Geneva, Dept Inorgan & Analyt Chem, Sci 2, 30 Quai Ernest Ansermet, CH-1205 Geneva, Switzerland..
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Kemi, Yt- och korrosionsvetenskap. Univ Geneva, Dept Inorgan & Analyt Chem, Sci 2, 30 Quai Ernest Ansermet, CH-1205 Geneva, Switzerland..
Univ Geneva, Dept Inorgan & Analyt Chem, Sci 2, 30 Quai Ernest Ansermet, CH-1205 Geneva, Switzerland..
Univ Geneva, Dept Inorgan & Analyt Chem, Sci 2, 30 Quai Ernest Ansermet, CH-1205 Geneva, Switzerland..
2018 (Engelska)Ingår i: Macromolecules, ISSN 0024-9297, E-ISSN 1520-5835, Vol. 51, nr 10, s. 3632-3639Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Single molecules of poly(vinyl amine) are analyzed in the adsorbed state by atomic force microscopy (AFM) in two different ways. First, high-resolution images of individual adsorbed polymers were recorded in monovalent electrolyte solutions. The backbone of the imaged polymers was digitized, and the directional correlation function and internal mean-square end-to-end distance were evaluated. These quantities were analyzed with the wormlike chain (WLC) model, and the persistence length was extracted. Second, individual polymer chains were picked up from the surface, and their force extension behavior was recorded in the same electrolyte solutions. These force profiles were also interpreted in terms of the WLC model, whereby the elastic contribution was also considered. Both techniques yield the persistence length of the polymer. From imaging one obtains a persistence length of about 1.6 nm, while the force experiments yield a value around 0.51 nm. We suspect that the force experiments reflect the intrinsic part of the persistence length, while the imaging experiments yield the persistence length including the electrostatic

Ort, förlag, år, upplaga, sidor
AMER CHEMICAL SOC , 2018. Vol. 51, nr 10, s. 3632-3639
Nationell ämneskategori
Kemi
Identifikatorer
URN: urn:nbn:se:kth:diva-230843DOI: 10.1021/acs.macromol.8b00834ISI: 000433404700009Scopus ID: 2-s2.0-85047556242OAI: oai:DiVA.org:kth-230843DiVA, id: diva2:1220168
Anmärkning

QC 20180618

Tillgänglig från: 2018-06-18 Skapad: 2018-06-18 Senast uppdaterad: 2024-03-15Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Radiom, Milad

Sök vidare i DiVA

Av författaren/redaktören
Radiom, Milad
Av organisationen
Yt- och korrosionsvetenskap
I samma tidskrift
Macromolecules
Kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 173 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf