A Comparative Study of Regulation Policies for Interruption of Supply of Electrical Distribution Systems in Sweden and UK
KTH, Skolan för elektro- och systemteknik (EES), Elektroteknisk teori och konstruktion.
KTH, Skolan för elektro- och systemteknik (EES), Elektroteknisk teori och konstruktion.ORCID-id: 0000-0001-6882-3642
KTH, Skolan för elektro- och systemteknik (EES), Elektroteknisk teori och konstruktion.ORCID-id: 0000-0003-4763-9429
2007 (Engelska)Ingår i: 19th International Conference on Electricity Distribution (CIRED), CIRED , 2007, s. 1-4Konferensbidrag, Publicerat paper (Övrigt vetenskapligt)
Abstract [en]

This paper presents a comparative study of regulating policies for interruption of supply in Sweden and UK. The two regulating regimes have been applied for a case study with a real rural electrical distribution system in Sweden, Flymen. The Swedish and UK regulations state that the distribution system operators (DSO) should restore power delivery to customers within 12 and 18 hours respectively for normal weather conditions. If this could not be fulfilled the DSOs are opposed to different predetermined penalty payments to the customers.

In a comparative case study of Flymen the Swedish model (GL) gives a 68% higher compensation to customers than the UK model (GS) for a 30 hours interruption of supply during normal weather conditions. Historical interruption data for the same system gives a 75% higher compensation with the Swedish model (GL) than the UK model (GS). The main conclusion from the comparative study is that the Swedish GL model provides a higher compensation for interruptions of supply to customers than the UK GS model.

Ort, förlag, år, upplaga, sidor
CIRED , 2007. s. 1-4
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:kth:diva-8311OAI: oai:DiVA.org:kth-8311DiVA, id: diva2:13597
Konferens
19th International Conference on Electricity Distribution, Vienna, 21-24 May 2007
Anmärkning
QC 20101125Tillgänglig från: 2012-02-03 Skapad: 2008-04-30 Senast uppdaterad: 2022-06-26Bibliografiskt granskad
Ingår i avhandling
1. On Risk Management of Electrical Distribution Systems and the Impact of Regulations
Öppna denna publikation i ny flik eller fönster >>On Risk Management of Electrical Distribution Systems and the Impact of Regulations
2008 (Engelska)Licentiatavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

The Swedish electricity market was de-regulated in 1996, followed by new laws and a new regulation applied to the natural monopolies of electrical distribution systems (EDS). These circumstances have motivated distribution systems operators (DSOs) to introduce more comprehensive analysis methods. The laws, the regulation and additional incentives have been investigated within this work and results from this study can be valuable when developing risk methods or other quantitative methods applied to EDS. This tendency is not unique for Sweden, the results from a comparative study of customer outage compensation laws between Sweden and UK is for example included.

As a part of investigating these incentives, studies of the Swedish regulation of customer network tariffs have been performed which provide valuable learning when developing regulation models in different countries. The Swedish regulatory model, referred to as the Network Performance Assessment Model (NPAM), was created for one of the first de-regulated electricity markets in the world and has a unique and novel approach. For the first time, an overall presentation of the NPAM has been performed including description of the underlying theory as a part of this work. However, the model has been met by difficulties and the future usage of the model is uncertain. Furthermore, the robustness of the NPAM has been evaluated in two studies with the main conclusion that the NPAM is sensitive toward small variations in input data. Results from these studies are explained theoretically investigating algorithms of the NPAM.

A pre-study of a project on developing international test systems is presented and this ongoing project aims to be a useful input when developing risk methods. An application study is included with the approach to systematically describe the overall risk management process at a DSO including an evaluation and ideas of future developments. The main objective is to support DSOs in the development of risk management, and to give academic reference material to utilize industry experience. An idea of a risk management classification has been concluded from this application study. The study provides an input to the final objective of a quantitative risk method.

Ort, förlag, år, upplaga, sidor
Stockholm: KTH, 2008. s. vii, 60
Serie
Trita-EE, ISSN 1653-5146 ; 2008:023
Nyckelord
Electrical Distribution System, Maintenance Management, Project Planning, Regulation, Reliability Analysis, Reliability Centred Maintenance (RCM), Reliability Centered Asset Management (RCAM), Risk Analysis, Risk Management, Risk Methods, the Network Performance Assessment Model (NPAM)
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
urn:nbn:se:kth:diva-4717 (URN)978-91-7178-954-9 (ISBN)
Presentation
2008-05-15, H1, Teknikringen 33, Teknikringen 33, Stockholm, 14:00
Opponent
Handledare
Anmärkning
QC 20101125Tillgänglig från: 2008-04-30 Skapad: 2008-04-30 Senast uppdaterad: 2022-06-26Bibliografiskt granskad

Open Access i DiVA

fulltext(216 kB)485 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 216 kBChecksumma SHA-512
ea3980889dff9c697e23293f39a719e602657197bbc4b997854aa508b4082e195036587038434febc7cb45baf59a5c9e1b9646ddbfbc1ca3fe93c0bc22348021
Typ fulltextMimetyp application/pdf

Övriga länkar

CIRED 2007

Person

Wallnerström, Carl JohanBertling, Lina

Sök vidare i DiVA

Av författaren/redaktören
Setréus, JohanWallnerström, Carl JohanBertling, Lina
Av organisationen
Elektroteknisk teori och konstruktion
Annan elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 489 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 675 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf