kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Energy and economic assessment of a polygeneration district heating and cooling system based on gasification of refuse derived fuels
KTH, Skolan för industriell teknik och management (ITM), Materialvetenskap. IDMEC, Department of Mechanical Engineering, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal.
KTH, Skolan för industriell teknik och management (ITM), Materialvetenskap.ORCID-id: 0000-0002-1837-5439
KTH, Skolan för industriell teknik och management (ITM), Energiteknik.ORCID-id: 0000-0002-3661-7016
2016 (Engelska)Ingår i: ECOS 2016: Proceedings of the 29th International Conference on Efficiency, Cost, Optimisation, Simulation and Environmental Impact of Energy Systems / [ed] Kitanovski A., Poredos A., University of Ljubljana , 2016Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Conventional district heating and cooling (DHC) systems have to reduce their fossil fuels dependence while ensuring profitability as the cooling and heating demands are decreasing. One of the solutions for these issues is to retrofit the system with a gasifier and product gas upgrading equipment so that the system will be able to diversify its fuel input, including biomass resources, and can simultaneously produce synthetic natural gas (SNG), synthetic gas (SG) and char complimentary to heat, cold and electricity. The main objective of this study is to assess energetically and economically a polygeneration DHC system, based on the gasification of refuse derived fuels, which is able to fabricate the following set of sub-products: char or SG and char or SNG and char or SG, SNG and char. This study revealed that when char is the only sub-product of the modified DHC system, the investment payback is 3 years, the discounted net cash flow (DNCF) is 142.4 mln USD, and the system trigeneration efficiency is 83.6%. When other sub-products are fabricated by the system, its performance reduces, but the system DNCF increases, while the investment payback remains invariable. 

Ort, förlag, år, upplaga, sidor
University of Ljubljana , 2016.
Nyckelord [en]
Cooling system, District heating, Gasification, Polygeneration
Nationell ämneskategori
Maskinteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-276535Scopus ID: 2-s2.0-85084244929OAI: oai:DiVA.org:kth-276535DiVA, id: diva2:1441769
Konferens
29th International Conference on Efficiency, Cost, Optimisation, Simulation and Environmental Impact of Energy Systems, ECOS 2016, Portoroz, Slovenia, 19-23 June 2016
Forskningsfinansiär
StandUp
Anmärkning

Part of proceedings: ISBN 978-961-6980-15-9

QC 20200616

Tillgänglig från: 2020-06-16 Skapad: 2020-06-16 Senast uppdaterad: 2026-03-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Scopus

Person

Kabalina, NataliaYang, WeihongMartin, Andrew R.

Sök vidare i DiVA

Av författaren/redaktören
Kabalina, NataliaYang, WeihongMartin, Andrew R.
Av organisationen
MaterialvetenskapEnergiteknik
Maskinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 183 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf