kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Frosting in heat pump evaporators part A: Experimental investigation
AIT Austrian Inst Technol, Ctr Energy, Sustainable Thermal Energy Syst, A-1210 Vienna, Austria..
KTH, Skolan för industriell teknik och management (ITM), Energiteknik. AIT Austrian Inst Technol, Ctr Energy, Sustainable Thermal Energy Syst, A-1210 Vienna, Austria..
AIT Austrian Inst Technol, Ctr Energy, Sustainable Thermal Energy Syst, A-1210 Vienna, Austria..
AIT Austrian Inst Technol, Ctr Energy, Sustainable Thermal Energy Syst, A-1210 Vienna, Austria.;Univ Kiel, Dept Geog, Kiel, Germany..
Visa övriga samt affilieringar
2021 (Engelska)Ingår i: Applied Thermal Engineering, ISSN 1359-4311, E-ISSN 1873-5606, Vol. 199, artikel-id 117487Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Frost growth on an evaporator of a 5 kW air-to-water heat pump assembly was analysed using several experimental approaches. For comparative testing, the evaporators fin and tube surfaces were treated with a hydrophobic nano-coating and the difference in frosting was investigated. Besides thermodynamic measurement data, transient frost mass and extracted frost layer thickness was available through the use of a scale and image capturing techniques, respectively. Images using a thermographic-, a macro- and overview-cameras were analysed for several climatic conditions established in a climate chamber. Time intervals between defrosting at +4.5 degrees C ambient temperature increased significantly by around 20% for the coated evaporator compared to the uncoated evaporator. This difference, however, got reduced when lowering the air inlet temperature below the freezing point, where this behaviour got reversed and the coated evaporator needed shorter intervals between defrosting compared to the uncoated one. This trend is also supported by the extracted frost thicknesses from the macro-camera image stream and by analysing the transient brightness signal of full evaporator image streams characterized in this work. Frost mass growth rate is reduced between 16% and 26% for -2.0 degrees C to +5.5 degrees C ambient temperature, respectively for the coated evaporator compared to the mass growth rate of the uncoated one. Parametric studies of evaporator frosting of this 5kW air-source heat pump at multiple air inlet stream conditions build up the base for comparison to the numerical work presented in Part B of this publication.

Ort, förlag, år, upplaga, sidor
Elsevier BV , 2021. Vol. 199, artikel-id 117487
Nyckelord [en]
Heat pump, Evaporator, Frost growth, Heat transfer
Nationell ämneskategori
Energiteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-304282DOI: 10.1016/j.applthermaleng.2021.117487ISI: 000707387100004Scopus ID: 2-s2.0-85114807608OAI: oai:DiVA.org:kth-304282DiVA, id: diva2:1607358
Anmärkning

QC 20211101

Tillgänglig från: 2021-11-01 Skapad: 2021-11-01 Senast uppdaterad: 2022-06-25Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Sandström, C.
Av organisationen
Energiteknik
I samma tidskrift
Applied Thermal Engineering
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 74 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf