The Impact of Aging-Preventive Algorithms on BESS Sizing under AGC Performance Standards
KTH, Skolan för elektroteknik och datavetenskap (EECS), Elektroteknik.ORCID-id: 0000-0003-2128-2425
Visa övriga samt affilieringar
2021 (Engelska)Ingår i: Energies, E-ISSN 1996-1073, Vol. 14, nr 21Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

It is normally accepted that Battery Energy Storage Systems improve frequency regulation by providing fast response to the Automatic Generation Control. However, currently available control strategies may lead to early Energy Storage Systems aging given that Automatic Generation Control requirements are increasing due to zero carbon power generation integration. In this sense, it is important to analyze the aging phenomena in order to assess the technical–economical usefulness of Battery Energy Storage Systems towards zero carbon power systems. In order to avoid early aging, various proposals on aging-reducing algorithms can be found; however, it is unclear if those aging-reducing algorithms affect the performance of Battery Energy Storage Systems. It is also unclear whether those effects must be internalized to properly dimension the capacity of Battery Energy Storage Systems to both comply with performance standards and to prevent early aging. Thus, this paper estimates the storage capacity of a Battery Energy Storage Systems to comply with Automatic Generation Control performance standard under aging-reducing operating algorithms by dynamics simulations of a reduced-order, empirically-validated model of the Electric Reliability Council of Texas. The results show the relationship between the required performance of Automatic Generation Control and Battery Energy Storage System capacity, considering a 1-year simulation of Automatic Generation Control dynamics. It can be concluded that the compliance with performance standards is strongly related to the storage capacity, regardless of how fast the device can inject or withdraw power from the grid. Previous results in the state-of-the-art overlook the quantification of this relationship between compliance with performance standards and storage capacity.

Ort, förlag, år, upplaga, sidor
MDPI AG , 2021. Vol. 14, nr 21
Nationell ämneskategori
Elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:kth:diva-304508DOI: 10.3390/en14217231ISI: 000718547200001Scopus ID: 2-s2.0-85118575047OAI: oai:DiVA.org:kth-304508DiVA, id: diva2:1608982
Anmärkning

QC 20220426

Tillgänglig från: 2021-11-05 Skapad: 2021-11-05 Senast uppdaterad: 2023-08-28Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopushttps://www.mdpi.com/1996-1073/14/21/7231

Person

Chamorro Vera, Harold Rene

Sök vidare i DiVA

Av författaren/redaktören
Chamorro Vera, Harold Rene
Av organisationen
Elektroteknik
I samma tidskrift
Energies
Elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 27 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf