kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Evaluation of a New Simplified Inertial Sensor Method against Electrogoniometer for Measuring Wrist Motion in Occupational Studies
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Medicinteknik och hälsosystem, Ergonomi.
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Medicinteknik och hälsosystem, Ergonomi. ;Karolinska Inst, Inst Environm Med, Unit Occupat Med, SE-17177 Stockholm, Sweden..ORCID-id: 0000-0001-7285-824x
2022 (Engelska)Ingår i: Sensors, E-ISSN 1424-8220, Vol. 22, nr 4, s. 1690-, artikel-id 1690Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Wrist velocity is an important risk factor for work-related musculoskeletal disorders in the elbow/hand, which is also difficult to assess by observation or self-reports. This study aimed to evaluate a new convenient and low-cost inertial measurement unit (IMU)-based method using gyroscope signals against an electrogoniometer for measuring wrist flexion velocity. Twelve participants performed standard wrist movements and simulated work tasks while equipped with both systems. Two computational algorithms for the IMU-based system, i.e., IMUnorm and IMUflex, were used. For wrist flexion/extension, the mean absolute errors (MAEs) of median wrist flexion velocity compared to the goniometer were <10.1 degrees/s for IMUnorm and <4.1 degrees/s for IMUflex. During wrist deviation and pronation/supination, all methods showed errors, where the IMUnorm method had the largest overestimations. For simulated work tasks, the IMUflex method had small bias and better accuracy than the IMUnorm method compared to the goniometer, with the MAEs of median wrist flexion velocity <5.8 degrees/s. The results suggest that the IMU-based method can be considered as a convenient method to assess wrist motion for occupational studies or ergonomic evaluations for the design of workstations and tools by both researchers and practitioners, and the IMUflex method is preferred. Future studies need to examine algorithms to further improve the accuracy of the IMU-based method in tasks of larger variations, as well as easy calibration procedures.

Ort, förlag, år, upplaga, sidor
MDPI AG , 2022. Vol. 22, nr 4, s. 1690-, artikel-id 1690
Nyckelord [en]
inertial measurement units, gyroscope, goniometer, wrist flexion velocity, work-related musculoskeletal disorders, ergonomics, hand-intensive work
Nationell ämneskategori
Produktionsteknik, arbetsvetenskap och ergonomi
Identifikatorer
URN: urn:nbn:se:kth:diva-310238DOI: 10.3390/s22041690ISI: 000767970700001PubMedID: 35214592Scopus ID: 2-s2.0-85124904854OAI: oai:DiVA.org:kth-310238DiVA, id: diva2:1647251
Anmärkning

QC 20220325

Tillgänglig från: 2022-03-25 Skapad: 2022-03-25 Senast uppdaterad: 2022-06-25Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Manivasagam, KarnicaYang, Liyun

Sök vidare i DiVA

Av författaren/redaktören
Manivasagam, KarnicaYang, Liyun
Av organisationen
Ergonomi
I samma tidskrift
Sensors
Produktionsteknik, arbetsvetenskap och ergonomi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 103 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf