kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Towards a standardisation for digital inputs and outputs of protection functions in IEC 60255 series
French Transmiss Network Operator Rte, Paris, France..
State Grid Jiangsu Elect Power Co Ltd, Nanjing, Peoples R China..
State Grid Elect Power Inst, Nanjing, Peoples R China..
KTH.
Visa övriga samt affilieringar
2022 (Engelska)Ingår i: PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, ISSN 2367-2617, Vol. 7, nr 1, artikel-id 26Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Fully digitalized substations using IEC 61850 process bus are being introduced all over the world. Numerous utilities have featured pilot projects, demonstrators or even industrial scale deployment of these Fully Digital Protection, Automation and Control Systems (FD-PACS). Product standards such as profiles for Instrument Transformers have been developed and published (IEC 61869-6 and IEC 61869-9 by TC 38-Instrument Transformers). This raises the question about the standards for digitally interfaced protection functions. In 2016, IEC TC 95 (Measuring relays and protection equipment) charged a working group to investigate this subject and to elaborate recommendations concerning requirements and testing of protection IED with digital inputs and outputs for protection standards (IEC 60255-1xx series). For protection functions, publisher/subscriber based data streams are supposed to comply with IEC 61850 and IEC 61869 standards. This holds in particular for Sampled Values (SV) representing energising inputs of the protection function, and is also applicable to Generic Object Oriented Substation Event (GOOSE) which can be used for input or output of protection functions. Quality attributes of published data depend on the operational and connection status of the function and the hosting IED. In addition, protection functions have to take into account the information regarding the time synchronisation of the received SV and other parameters. This paper gives an overview of these features and the proposed way to take them into account in the IEC 60255 standard series. It describes the progress of WG 2 and relates it to existing standardization documents.

Ort, förlag, år, upplaga, sidor
Springer Nature , 2022. Vol. 7, nr 1, artikel-id 26
Nyckelord [en]
Process bus, Protection function, Digital interface, SAMU, LPIT, Standards, IEC 61850
Nationell ämneskategori
Energiteknik Annan maskinteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-315923DOI: 10.1186/s41601-022-00246-xISI: 000824603300001Scopus ID: 2-s2.0-85134370258OAI: oai:DiVA.org:kth-315923DiVA, id: diva2:1684739
Anmärkning

QC 20220728

Tillgänglig från: 2022-07-28 Skapad: 2022-07-28 Senast uppdaterad: 2022-07-28Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Bonetti, Andrea
Av organisationen
KTH
EnergiteknikAnnan maskinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 41 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf