kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Dual-Energy: The GE Approach
KTH, Skolan för teknikvetenskap (SCI), Fysik, Medicinsk bildfysik.ORCID-id: 0000-0002-3039-9791
2022 (Engelska)Ingår i: Spectral Imaging, Springer Nature , 2022, s. 45-62Kapitel i bok, del av antologi (Övrigt vetenskapligt)
Abstract [en]

This chapter provides an overview of the GE Dual-Energy Approach to Spectral Imaging known as Gemstone Spectral Imaging (GSI). Since 2010 when GE launched GSI on Discovery™ CT750 HD, GE has provided continued improvements to the technology, capabilities, and workflow, as well as spectral clinical tools to support advances in diagnosis and solutions across the Discovery™ GSI, Revolution™ CT Frontier, and Revolution™ CT/Revolution™ Apex platforms. The GSI acquisition method enables precise temporal registration of the dual-energy sinograms, projection-based material decomposition, and delivers a full 50 cm material decomposition scan field of view. The technologies employed to achieve the dual-energy acquisitions are detailed in the discussion of balanced system design below. Calibration of fast kVp switching data, material decomposition, and visualization of the resulting images are covered in the image reconstruction, projection-based material decomposition, and post-processing/clinical applications sections. The chapter closes with GSI implementation in the context of workflow, imaging improvements, solutions to challenging diagnostic applications, and the path to the future of photon counting. Academic research and clinical exploration of GSI have grown rapidly and resulted in rich scientific publications and extensive clinical adoption. GSI has shown benefits in: Better lesion characterization by providing information about the chemical composition and material characteristicsImproving lesion detection with enhanced contrast-to-noise ratioReducing beam hardening and metal artifactsOptimizing iodine load in contrast enhanced CT studies.

Ort, förlag, år, upplaga, sidor
Springer Nature , 2022. s. 45-62
Serie
Medical Radiology, ISSN 0942-5373
Nyckelord [en]
Dual energy, Gemstone spectral imaging, GSI, Photon counting, Quantitative imaging, Spectral imaging
Nationell ämneskategori
Medicinteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-318010DOI: 10.1007/978-3-030-96285-2_4Scopus ID: 2-s2.0-85129722931OAI: oai:DiVA.org:kth-318010DiVA, id: diva2:1696337
Anmärkning

QC 20220916

Part of book: ISBN  978-3-030-96284-5

Tillgänglig från: 2022-09-16 Skapad: 2022-09-16 Senast uppdaterad: 2022-09-16Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Danielsson, Mats

Sök vidare i DiVA

Av författaren/redaktören
Danielsson, Mats
Av organisationen
Medicinsk bildfysik
Medicinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 426 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf