kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Thermal energy storage based on cold phase change materials: Charge phase assessment
Univ Genoa, DIME, I-16145 Genoa, Italy..
Univ Genoa, DIME, I-16145 Genoa, Italy..
Univ Genoa, DIME, I-16145 Genoa, Italy..
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Kraft- och värmeteknologi.ORCID-id: 0000-0001-6982-2879
2022 (Engelska)Ingår i: Applied Thermal Engineering, ISSN 1359-4311, E-ISSN 1873-5606, Vol. 217, artikel-id 119177Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Integration of thermal energy storage in energy systems provides flexibility in demand-supply management and in supporting novel operational schemes. In a combined heat and power cycle, it has been shown that integration of cold thermal energy storage is beneficial to fine-tune electric power and heating/cooling production profiles to better match the load demand. Latent heat storage systems have the advantage of compactness and low temperature swing, however storage performance analysis on large scale setup operating around the density inversion temperature is still limited. In this work, a shell & tube, latent heat based cold thermal energy storage was studied around the density inversion temperature of ice-water at 4 degrees C and the performance was characterized. Sensitivity analyses on heat transfer fluid flow rate, flow direction and inlet temperature were performed. The results show 27% power increase with doubled mass flow and 18% shorter charge time with 2 degrees C lower charge temperature. Contrary to general expectations during solidification, the cold thermal energy storage actually shows between 5% and 6% better thermal performance and reducing instant icing power jump of 36% due to supercooling with downwards cold heat transfer fluid flow in cooling charge cycle due to buoyancy change around density inversion temperature. This fact highlights the importance of accounting for the buoyancy effect due to density inversion when designing the operational schemes of large size cold thermal energy storage.

Ort, förlag, år, upplaga, sidor
Elsevier BV , 2022. Vol. 217, artikel-id 119177
Nyckelord [en]
Thermal energy storage, Phase change material, State of charge, Heat transfer fluid, Finned shell & tube
Nationell ämneskategori
Nationalekonomi Annan fysik Idrottsvetenskap och fitness
Identifikatorer
URN: urn:nbn:se:kth:diva-319829DOI: 10.1016/j.applthermaleng.2022.119177ISI: 000860478100002Scopus ID: 2-s2.0-85136592761OAI: oai:DiVA.org:kth-319829DiVA, id: diva2:1702894
Anmärkning

QC 20221012

Tillgänglig från: 2022-10-12 Skapad: 2022-10-12 Senast uppdaterad: 2025-02-11Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Chiu, Justin NingWei

Sök vidare i DiVA

Av författaren/redaktören
Chiu, Justin NingWei
Av organisationen
Kraft- och värmeteknologi
I samma tidskrift
Applied Thermal Engineering
NationalekonomiAnnan fysikIdrottsvetenskap och fitness

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 203 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf