kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Simulation and experimental verification of ambient neutron doses in a pencil beam scanning proton therapy room as a function of treatment plan parameters
Belgian Nucl Res Ctr SCK CEN, Inst Environm, Hlth & Safety EHS, Mol, Belgium..
Aarhus Univ Hosp AUH, Danish Ctr Particle Therapy, Aarhus, Denmark.;Inst Nucl Phys, Polish Acad Sci, IFJ PAN, Krakow, Poland.;Skandion Clin, Uppsala, Sweden..
Swedish Radiat Safety Author, Solna, Sweden..
KTH, Skolan för teknikvetenskap (SCI), Fysik.ORCID-id: 0000-0003-1478-0856
Visa övriga samt affilieringar
2022 (Engelska)Ingår i: Frontiers in Oncology, E-ISSN 2234-943X, Vol. 12, artikel-id 903537Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Out-of-field patient doses in proton therapy are dominated by neutrons. Currently, they are not taken into account by treatment planning systems. There is an increasing need to include out-of-field doses in the dose calculation, especially when treating children, pregnant patients, and patients with implants. In response to this demand, this work presents the first steps towards a tool for the prediction of out-of-field neutron doses in pencil beam scanning proton therapy facilities. As a first step, a general Monte Carlo radiation transport model for simulation of out-of-field neutron doses was set up and successfully verified by comparison of simulated and measured ambient neutron dose equivalent and neutron fluence energy spectra around a solid water phantom irradiated with a variation of different treatment plan parameters. Simulations with the verified model enabled a detailed study of the variation of the neutron ambient dose equivalent with field size, range, modulation width, use of a range shifter, and position inside the treatment room. For future work, it is planned to use this verified model to simulate out-of-field neutron doses inside the phantom and to verify the simulation results by comparison with previous in-phantom measurement campaigns. Eventually, these verified simulations will be used to build a library and a corresponding tool to allow assessment of out-of-field neutron doses at pencil beam scanning proton therapy facilities.

Ort, förlag, år, upplaga, sidor
Frontiers Media SA , 2022. Vol. 12, artikel-id 903537
Nyckelord [en]
Proton therapy, Pencil beam scanned proton therapy, Neutron doses, Monte Carlo simulations, Out-of-field neutron doses in radiation therapy, Neutron measurements
Nationell ämneskategori
Radiologi och bildbehandling Cancer och onkologi
Identifikatorer
URN: urn:nbn:se:kth:diva-322220DOI: 10.3389/fonc.2022.903537ISI: 000884350700001PubMedID: 36158693Scopus ID: 2-s2.0-85136947416OAI: oai:DiVA.org:kth-322220DiVA, id: diva2:1716286
Anmärkning

QC 20221205

Tillgänglig från: 2022-12-05 Skapad: 2022-12-05 Senast uppdaterad: 2024-01-17Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Eliasson, Linda

Sök vidare i DiVA

Av författaren/redaktören
Eliasson, Linda
Av organisationen
Fysik
I samma tidskrift
Frontiers in Oncology
Radiologi och bildbehandlingCancer och onkologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 39 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf