kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Chemical mass shifts of cluster ions and adduct ions in quadrupolar ion traps revisited and extended
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Kemi, Organisk kemi.ORCID-id: 0000-0003-3091-3882
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Kemi, Tillämpad fysikalisk kemi.ORCID-id: 0000-0002-3444-9987
2023 (Engelska)Ingår i: Rapid Communications in Mass Spectrometry, ISSN 0951-4198, E-ISSN 1097-0231, Vol. 37, nr 3, artikel-id e9436Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

RationaleChemical mass shifts in quadrupolar ion traps have been studied previously but only for a limited number of analytes and mass ranges. Here, mass shifts of cluster ions, commonly used as calibrants, and other analytes are qualitatively evaluated on the Bruker amaZon spherical ion trap (QIT) and the Finnigan LXQ linear ion trap (LIT). To extend the mass range from previous experiments m/z up to 4000 are investigated. MethodsChemical mass shifts of CsI, Y(HCOO)(3), and NaCF3COO cluster ions, CF3COO-, Na+, and Cs+ adduct ions, protonated commercial calibration solutions and peptides, and deprotonated peptides were investigated on the Bruker amaZon speed QIT and some of these were also investigated on the Finnigan LXQ LIT. ResultsOn both instruments, peak distortions and mass shifts toward lower m/z became apparent as m/z approached 1000. To some extent, the issues were more severe at slower scans. Peak distortions included loss of resolution, tailing, or fronting and were different between the amaZon QIT and the LXQ LIT. The noncluster and nonadduct ions analyzed showed no obvious mass shifts or peak distortions under the same analysis conditions. ConclusionsAs expected, the ion traps investigated here showed mass shift and peak distortion issues, and such issues persisted at m/z up to 4000 on both instruments. Peak distortions were different between the amaZon QIT and the LXQ LIT, and were not always visible despite mass shifts. Both mass shifts and peak distortions make cluster ions and some adduct ions unsuitable for ion trap calibration.

Ort, förlag, år, upplaga, sidor
Wiley , 2023. Vol. 37, nr 3, artikel-id e9436
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:kth:diva-322849DOI: 10.1002/rcm.9436ISI: 000897104500001PubMedID: 36410697Scopus ID: 2-s2.0-85145955722OAI: oai:DiVA.org:kth-322849DiVA, id: diva2:1724741
Anmärkning

QC 20230109

Tillgänglig från: 2023-01-09 Skapad: 2023-01-09 Senast uppdaterad: 2023-06-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Romson, JoakimEmmer, Åsa

Sök vidare i DiVA

Av författaren/redaktören
Romson, JoakimEmmer, Åsa
Av organisationen
Organisk kemiTillämpad fysikalisk kemi
I samma tidskrift
Rapid Communications in Mass Spectrometry
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 256 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf