kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Optical amplification-free deep reservoir computing-assisted high-baudrate short-reach communication
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik. Beijing Jiaotong Univ, Inst Lightwave Technol, Key Lab All Opt Network & Adv Telecommun Network, Minist Educ, Beijing 100044, Peoples R China..
Beijing Jiaotong Univ, Inst Lightwave Technol, Key Lab All Opt Network & Adv Telecommun Network, Minist Educ, Beijing 100044, Peoples R China..
RISE Res Inst Sweden, S-16440 Kista, Sweden..ORCID-id: 0000-0001-5783-8996
Riga Tech Univ, Inst Telecommun, LV-1048 Riga, Latvia.;Riga Tech Univ, Commun Technol Res Ctr, LV-1048 Riga, Latvia..
Visa övriga samt affilieringar
2023 (Engelska)Ingår i: Optics Letters, ISSN 0146-9592, E-ISSN 1539-4794, Vol. 48, nr 8, s. 2122-2125Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

An optical amplification-free deep reservoir computing (RC)-assisted high-baudrate intensity modulation direct detection (IM/DD) system is experimentally demonstrated using a 100G externally modulated laser operated in C-band. We transmit 112 Gbaud 4-level pulse amplitude modulation (PAM4) and 100 Gbaud 6-level PAM (PAM6) signals over a 200-m single-mode fiber (SMF) link without any optical amplification. The decision feedback equalizer (DFE), shal-low RC, and deep RC are adopted in the IM/DD system to mitigate impairment and improve transmission perfor-mance. Both PAM transmissions over a 200-m SMF with bit error rate (BER) performance below 6.25% overhead hard-decision forward error correction (HD-FEC) thresh-old are achieved. In addition, the BER of the PAM4 signal is below the KP4-FEC limit after 200-m SMF transmis-sion enabled by the RC schemes. Thanks to the use of a multiple-layer structure, the number of weights in deep RC has been reduced by approximately 50% compared with the shallow RC, whereas the performance is comparable. We believe that the optical amplification-free deep RC-assisted high-baudrate link has a promising application in intra-data center communications.

Ort, förlag, år, upplaga, sidor
Optica Publishing Group , 2023. Vol. 48, nr 8, s. 2122-2125
Nationell ämneskategori
Telekommunikation
Identifikatorer
URN: urn:nbn:se:kth:diva-329889DOI: 10.1364/OL.485830ISI: 000981300700001PubMedID: 37058657Scopus ID: 2-s2.0-85152545796OAI: oai:DiVA.org:kth-329889DiVA, id: diva2:1774486
Anmärkning

QC 20230626

Tillgänglig från: 2023-06-26 Skapad: 2023-06-26 Senast uppdaterad: 2024-03-18Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Han, MengyaoFan, YuchuanSchatz, RichardPopov, SergeiPang, XiaodanOzolins, Oskars

Sök vidare i DiVA

Av författaren/redaktören
Han, MengyaoFan, YuchuanSchatz, RichardPopov, SergeiPang, XiaodanOzolins, Oskars
Av organisationen
Tillämpad fysik
I samma tidskrift
Optics Letters
Telekommunikation

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 138 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf