kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Mesoporous carbon-based sensor for quantification of prasugrel in solubilized system
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Fiber- och polymerteknologi, Polymera material.ORCID-id: 0000-0002-8987-8914
Environmental Chemistry, Jiwaji University, Gwalior-474011, India.
Environmental Chemistry, Jiwaji University, Gwalior-474011, India.
Environmental Chemistry, Jiwaji University, Gwalior-474011, India.
2023 (Engelska)Ingår i: Journal of the Indian Chemical Society, ISSN 0019-4522, Vol. 100, nr 9, artikel-id 101079Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In this study, a mesoporous carbon-based electrochemical sensor has been made up, possessing the novelty for ultra-sensitive detecting Prasugrel in pharmaceutical formulation and biological samples. Mesoporous carbon has even and tunable pore size, greater surface area, with excellent, electrical conductivity, wide availability and also have unique surface functionalization properties which make them significant sensing material now a days. Determination of prasugrel was accomplished with mesoporous carbon/GCE sensor on square-wave and cyclic voltammetry. Effects of various environmental and instrumental parameters like effect of buffer, casting volume, solvent, and pH on peak signal have been optimized. The best results were obtained in 0.1% cetyltrimethylammonium bromide - aqueous 0.1 M potassium chloride–phosphate buffer (pH 5.3). The limit of detection and quantification of the pure drug was found to be 37.0 ng mL−1 and 110.0 ng mL−1 (with the correlation coefficient, r = 0.988 and the standard deviation, (S.D.) = 0.6 (n = 6), respectively. The fabricated sensor was efficaciously validated by the determination of the drug in pharmaceutical formulation. Recoveries obtained were 97.84–99.37%.

Ort, förlag, år, upplaga, sidor
Elsevier BV , 2023. Vol. 100, nr 9, artikel-id 101079
Nyckelord [en]
Electrochemical sensor, Mesoporous carbon, Prasugrel, Surfactant, Voltammetry
Nationell ämneskategori
Analytisk kemi Polymerteknologi
Identifikatorer
URN: urn:nbn:se:kth:diva-334945DOI: 10.1016/j.jics.2023.101079ISI: 001095921100001Scopus ID: 2-s2.0-85168327572OAI: oai:DiVA.org:kth-334945DiVA, id: diva2:1792857
Anmärkning

QC 20230830

Tillgänglig från: 2023-08-30 Skapad: 2023-08-30 Senast uppdaterad: 2023-11-30Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Pandey, Annu

Sök vidare i DiVA

Av författaren/redaktören
Pandey, Annu
Av organisationen
Polymera material
I samma tidskrift
Journal of the Indian Chemical Society
Analytisk kemiPolymerteknologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 118 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf