kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Automated electrolyte formulation and coin cell assembly for high-throughput lithium-ion battery research
Department of Chemistry, Ångström Laboratory, Uppsala University, P.O. Box 538, SE-751 21 Uppsala, Sweden., P.O. Box 538.
Department of Chemistry, Ångström Laboratory, Uppsala University, P.O. Box 538, SE-751 21 Uppsala, Sweden., P.O. Box 538.
Department of Information Technology, Uppsala University, P.O. Box 337, SE-751 05 Uppsala, Sweden, P.O. Box 337.
Department of Chemistry, Ångström Laboratory, Uppsala University, P.O. Box 538, SE-751 21 Uppsala, Sweden., P.O. Box 538.
Visa övriga samt affilieringar
2023 (Engelska)Ingår i: Digital Discovery, E-ISSN 2635-098X, Vol. 2, nr 3, s. 799-808Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Battery cell assembly and testing in conventional battery research is acknowledged to be heavily time-consuming and often suffers from large cell-to-cell variations. Manual battery cell assembly and electrolyte formulations are prone to introducing errors which confound optimization strategies and upscaling. Herein we present ODACell, an automated electrolyte formulation and battery assembly setup, capable of preparing large batches of coin cells. We demonstrate the feasibility of Li-ion cell assembly in an ambient atmosphere by preparing LiFePO4⃦Li4Ti5O12-based full cells with dimethyl sulfoxide-based model electrolyte. Furthermore, the influence of water is investigated to account for the hygroscopic nature of the non-aqueous electrolyte when exposed to ambient atmosphere. The reproducibility tests demonstrate a conservative fail rate of 5%, while the relative standard deviation of the discharge capacity after 10 cycles was 2% for the studied system. The groups with 2 vol% and 4 vol% of added water in the electrolyte showed overlapping performance trends, highlighting the nontrivial relationship between water contaminants in the electrolytes and the cycling performance. Thus, reproducible data are essential to ascertain whether or not there are minor differences in the performance for high-throughput electrolyte screenings. ODACell is broadly applicable to coin cell assembly with liquid electrolytes and therefore presents an essential step towards accelerating research and development of such systems.

Ort, förlag, år, upplaga, sidor
Royal Society of Chemistry (RSC) , 2023. Vol. 2, nr 3, s. 799-808
Nationell ämneskategori
Materialkemi
Identifikatorer
URN: urn:nbn:se:kth:diva-336703DOI: 10.1039/d3dd00058cISI: 001121110000001Scopus ID: 2-s2.0-85168704405OAI: oai:DiVA.org:kth-336703DiVA, id: diva2:1798205
Anmärkning

QC 20230918

Tillgänglig från: 2023-09-18 Skapad: 2023-09-18 Senast uppdaterad: 2024-02-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Svensson, Per H.

Sök vidare i DiVA

Av författaren/redaktören
Svensson, Per H.
Av organisationen
Tillämpad fysikalisk kemi
I samma tidskrift
Digital Discovery
Materialkemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 123 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf