kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Experimental Evaluation of a Micron-Resolution CT Detector
KTH, Skolan för teknikvetenskap (SCI), Fysik. MedTechLabs, BioClinicum, Karolinska University Hospital, Solna, Sweden, 17164.ORCID-id: 0000-0002-3309-9276
KTH, Skolan för teknikvetenskap (SCI), Fysik. MedTechLabs, BioClinicum, Karolinska University Hospital, Solna, Sweden, 17164.ORCID-id: 0000-0002-5092-8822
KTH, Skolan för teknikvetenskap (SCI), Fysik.
KTH, Skolan för teknikvetenskap (SCI), Fysik. MedTechLabs, BioClinicum, Karolinska University Hospital, Solna, Sweden, 17164.ORCID-id: 0000-0002-3039-9791
2024 (Engelska)Ingår i: Medical Imaging 2024: Physics of Medical Imaging, SPIE-Intl Soc Optical Eng , 2024, Vol. 12925, artikel-id 129250BKonferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Purpose: Current photon-counting detectors are limited to a pixel size of 0.3 mm-1 mm, as decreasing the pixel size further generally introduces degraded dose efficiency and energy resolution from excessive charge sharing. In this work, we present experimental measurements of the first photon-counting detector prototype designed to leverage the charge sharing to estimate the photon interaction position, where simulations indicate a theoretical resolution of around 1 µm using a similar geometry. The goal of the measurements is to validate our Monte-Carlo simulation for further development. Approach: DAC sweeps are performed with an X-ray beam at specified locations on the sensor front, with the beam at 20 keV and 35 keV, as well as with different sensor biases with the beam at 35 keV. The experimental data are then compared to a Monte Carlo simulation combined with a charge transport model. In this first prototype wire bonds are used, and as such only a few channels are connected. Results: The experimental data agree generally well with the simulated data with the beam close to the electrodes, with the simulated data diverging from the experiments with the beam further away from the electrodes. The induced charge cloud signal exhibits a fairly linear dependency on the beam position, indicating that any estimation techniques will yield more precise position when the photon interacts further away from the electrodes, rather than closer. Conclusions: With the experimental data and the simulations agreeing generally well, together with the same software previously indicating a resolution of around 1 µm, we expect an ultra-high-resolution detector to be in reach, and are encouraged to continue development.

Ort, förlag, år, upplaga, sidor
SPIE-Intl Soc Optical Eng , 2024. Vol. 12925, artikel-id 129250B
Serie
Progress in Biomedical Optics and Imaging - Proceedings of SPIE, ISSN 1605-7422 ; 12925
Nationell ämneskategori
Fysik
Identifikatorer
URN: urn:nbn:se:kth:diva-347132DOI: 10.1117/12.2692858ISI: 001223517100008Scopus ID: 2-s2.0-85193488296OAI: oai:DiVA.org:kth-347132DiVA, id: diva2:1864381
Konferens
Medical Imaging 2024: Physics of Medical Imaging, San Diego, United States of America, Feb 19 2024 - Feb 22 2024
Anmärkning

QC 20240605

Part of ISBN 978-151067154-6

Tillgänglig från: 2024-06-03 Skapad: 2024-06-03 Senast uppdaterad: 2024-06-14Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Brunskog, RickardPersson, MatsJin, ZihuiDanielsson, Mats

Sök vidare i DiVA

Av författaren/redaktören
Brunskog, RickardPersson, MatsJin, ZihuiDanielsson, Mats
Av organisationen
Fysik
Fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 330 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf