kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Strain sensing, electromagnetic interference shielding, and antimicrobial performance of triple hierarchic fabric coated with AgNWs and polydopamine
School of Automobile and Transportation Engineering, Guangdong Polytechnic Normal University, Guangdong, China; Institute of Polymer Materials, Friedrich-Alexander-University Erlangen-Nuremberg, Martensstr. 7, 91058 Erlangen, Germany, Martensstr. 7.
School of Automobile and Transportation Engineering, Guangdong Polytechnic Normal University, Guangdong, China.
School of Automobile and Transportation Engineering, Guangdong Polytechnic Normal University, Guangdong, China.
Institute of Polymer Materials, Friedrich-Alexander-University Erlangen-Nuremberg, Martensstr. 7, 91058 Erlangen, Germany, Martensstr. 7.
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: Materials & design, ISSN 0264-1275, E-ISSN 1873-4197, Vol. 243, artikel-id 113033Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

For wearable smart textile sensors, stability, accuracy and multi-functionality are key objectives. Achieving the optimal application requires delicately balancing the crucial physical properties of strain sensors, presenting a key technological challenge. This study addresses these challenges by presenting several properties and potential applications of a triple hierarchic polymeric knitted fabric. The fabric incorporates an internal conductive network constructed with silver nanowires (AgNWs) and polydopamine (PDA) coating on its outer surface. This innovative textile successfully strikes a balance between strain sensing and electromagnetic interference shielding while concurrently exhibiting biocompatibility and antimicrobial properties. Significantly, acknowledging the susceptibility of measurements from polymer-based strain sensor materials to time drift, we introduce both a modeling approach and a novel calibration technique. This advancement facilitates the generation of stable cyclic sensing signals, even under substantial deformations of up to 80 % at a high stretching speed. Importantly, it provides a practical solution for addressing signal drift observed in flexible sensors when utilized in environments characterized by long-term and large deformations.

Ort, förlag, år, upplaga, sidor
Elsevier BV , 2024. Vol. 243, artikel-id 113033
Nyckelord [en]
Coating, Composites, Mechanical properties, Multifunctionality, Physical modelling
Nationell ämneskategori
Materialteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-347291DOI: 10.1016/j.matdes.2024.113033ISI: 001246993200001Scopus ID: 2-s2.0-85194279585OAI: oai:DiVA.org:kth-347291DiVA, id: diva2:1867223
Anmärkning

QC 20240612

Tillgänglig från: 2024-06-10 Skapad: 2024-06-10 Senast uppdaterad: 2024-07-03Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Nilsson, Fritjof

Sök vidare i DiVA

Av författaren/redaktören
Nilsson, Fritjof
Av organisationen
Polymera material
I samma tidskrift
Materials & design
Materialteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 54 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf