kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
The influence of activity patterns and relative humidity on particle resuspension in classrooms
Joint International Research Laboratory of Green Buildings and Built Environments (Ministry of Education), Chongqing University, Chongqing, 400045, China.
Joint International Research Laboratory of Green Buildings and Built Environments (Ministry of Education), Chongqing University, Chongqing, 400045, China; School of the Built Environment, University of Reading, UK.
KTH, Skolan för arkitektur och samhällsbyggnad (ABE), Byggvetenskap, Byggteknik och design.ORCID-id: 0000-0002-9361-1796
School of the Built Environment, University of Reading, UK.
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: Science of the Total Environment, ISSN 0048-9697, E-ISSN 1879-1026, Vol. 946, artikel-id 173898Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

This paper investigates the impact of children's recess activity patterns on particulate matter (PM) resuspension in indoor environments, highlighting the complex, multi-dimensional nature of these activities and their interaction with environmental parameters. Despite the recognized role of indoor human activity in PM resuspension, research specifically addressing the effects of children's movements has been sparse. Through experimental scenarios that account for the characteristics of student activities, such as movement speed, trajectory, the number of participants, aisle widths, and varying humidity levels, this study uncovers significant differences in PM resuspension rates. It reveals that not only do movement speed and trajectory have a profound impact, but also the interaction between humidity and these factors plays a critical role, especially under lower humidity conditions. Additionally, the study demonstrates how the combination of people density and spatial configurations can significantly influence resuspension rates. The findings offer valuable insights for designing strategies to mitigate particle pollution in classrooms and similar indoor environments.

Ort, förlag, år, upplaga, sidor
Elsevier BV , 2024. Vol. 946, artikel-id 173898
Nyckelord [en]
Activity patterns, Indoor air quality, Particle resuspension, Relative humidity
Nationell ämneskategori
Arbetsmedicin och miljömedicin
Identifikatorer
URN: urn:nbn:se:kth:diva-349924DOI: 10.1016/j.scitotenv.2024.173898ISI: 001266611400001PubMedID: 38866141Scopus ID: 2-s2.0-85196768603OAI: oai:DiVA.org:kth-349924DiVA, id: diva2:1881708
Anmärkning

QC 20240708

Tillgänglig från: 2024-07-03 Skapad: 2024-07-03 Senast uppdaterad: 2024-08-20Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Sadrizadeh, Sasan

Sök vidare i DiVA

Av författaren/redaktören
Sadrizadeh, Sasan
Av organisationen
Byggteknik och design
I samma tidskrift
Science of the Total Environment
Arbetsmedicin och miljömedicin

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 85 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf