kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Microfabricated Biosensor for Detection of Disease Biomarkers Based on Streaming Current Method
KTH, Skolan för elektroteknik och datavetenskap (EECS), Intelligenta system, Mikro- och nanosystemteknik. Gatty Instruments AB, Ulls Väg 29C, 75651, Uppsala, Sweden; Department of Mechatronics, Manipal Institute of Technology, Manipal, India.ORCID-id: 0000-0001-8935-2149
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Fotonik.ORCID-id: 0000-0002-5260-5322
KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik, Fotonik.ORCID-id: 0000-0002-6235-2891
2023 (Engelska)Ingår i: Intelligent Control, Robotics, and Industrial Automation - Proceedings of International Conference, RCAAI 2022, Springer Nature , 2023, s. 715-723Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

A microfabricated biosensor based on the streaming current method is presented in this work. The microfabricated sensor consists of a silicon microchannel, which is enclosed with a glass capping to form a closed microchannel. The depth of the microchannel is approximately 10 µm in width and length varying from 50 to 100 µm. The silicon is etched using deep reactive ion etching (DRIE) to form a microchannel. For the capping of the channel, a glass wafer of type Borofloat is used and anodically bonded to the silicon wafer to form a closed microchannel. The microchannel is then functionalized to be specific to certain biomarkers which can be a potential biomarker for cancer, for example. The method used for detection is called the streaming current method. In this method, fluid is flown through the microchannel with high pressure close to six bars. The surface of the silicon is oxidized, which has a zeta potential of approximately 2.7. Depending on the type of fluid the charge concentration varies. By having a pressure in the channel, the charges get distributed as an anode and cathode at the inlet and outlet electrodes of the microfluidic channels. At a fixed potential, a streaming current is observed, which is proportional to the charge accumulated. The difference between the streaming current with and without the biomarker is correlated to the concentration. Hence, a biosensor based on the streaming current method can be realized, which could be used for potential cancer biomarker detection.

Ort, förlag, år, upplaga, sidor
Springer Nature , 2023. s. 715-723
Nyckelord [en]
Biosensor streaming current, Microfluidics, Microsensor, Silicon
Nationell ämneskategori
Annan fysik
Identifikatorer
URN: urn:nbn:se:kth:diva-350242DOI: 10.1007/978-981-99-4634-1_56Scopus ID: 2-s2.0-85177863144OAI: oai:DiVA.org:kth-350242DiVA, id: diva2:1883625
Konferens
International Conference on Robotics, Control, Automation and Artificial Intelligence, RCAAI 2022, Virtual, Online, NA, Nov 24 2022 - Nov 26 2022
Anmärkning

Part of ISBN 9789819946334

QC 20240711

Tillgänglig från: 2024-07-11 Skapad: 2024-07-11 Senast uppdaterad: 2024-07-11Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Gatty, Hithesh K.Linnros, JanDev, Apurba

Sök vidare i DiVA

Av författaren/redaktören
Gatty, Hithesh K.Linnros, JanDev, Apurba
Av organisationen
Mikro- och nanosystemteknikFotonik
Annan fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 100 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf