kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Measurements in a Turbulent Channel Flow by Means of an LDV Profile Sensor
Institute of Fluids Mechanics (ISTM), Karlsruhe Institute of Technology (KIT), Kaiserstraße 10, 76131, Karlsruhe, Germany, Kaiserstraße 10.
Institute of Fluids Mechanics (ISTM), Karlsruhe Institute of Technology (KIT), Kaiserstraße 10, 76131, Karlsruhe, Germany, Kaiserstraße 10.
Institute of Fluids Mechanics (ISTM), Karlsruhe Institute of Technology (KIT), Kaiserstraße 10, 76131, Karlsruhe, Germany, Kaiserstraße 10.
KTH, Skolan för teknikvetenskap (SCI), Centra, Linné Flow Center, FLOW. KTH, Skolan för teknikvetenskap (SCI), Teknisk mekanik, Strömningsmekanik och Teknisk Akustik.ORCID-id: 0000-0002-1663-3553
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: Flow Turbulence and Combustion, ISSN 1386-6184, E-ISSN 1573-1987, Vol. 113, nr 1, s. 195-213Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Spatially and temporally resolved velocity measurements in wall-bounded turbulent flows remain a challenge. Contrary to classical laser Doppler velocimetry (LDV) measurements, the laser Doppler velocity profile sensor (LDV-PS) allows the combined measurement of tracer particle position and velocity, which makes it a promising tool. To assess its feasibility a commercial LDV-PS is employed in a turbulent channel flow at Reτ= 350 . Additionally, the measurement and signal-processing accuracies of velocity and location are evaluated for various tracer-object sizes and velocities. On this basis, the turbulent channel flow measurements are evaluated and compared to reference data from direct numerical simulations. Thus, potentials of the LDV-PS are investigated for different regions of the flow and various data processing routines as well as the experimental practice are discussed from an application perspective.

Ort, förlag, år, upplaga, sidor
Springer Nature , 2024. Vol. 113, nr 1, s. 195-213
Nyckelord [en]
LDV profile sensor, Near-wall measurements, Turbulent channel flow
Nationell ämneskategori
Strömningsmekanik
Identifikatorer
URN: urn:nbn:se:kth:diva-350320DOI: 10.1007/s10494-023-00469-4ISI: 001063147700001Scopus ID: 2-s2.0-85170404471OAI: oai:DiVA.org:kth-350320DiVA, id: diva2:1883819
Anmärkning

QC 20240711

Tillgänglig från: 2024-07-11 Skapad: 2024-07-11 Senast uppdaterad: 2025-02-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Örlü, Ramis

Sök vidare i DiVA

Av författaren/redaktören
Örlü, Ramis
Av organisationen
Linné Flow Center, FLOWStrömningsmekanik och Teknisk Akustik
I samma tidskrift
Flow Turbulence and Combustion
Strömningsmekanik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 125 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf