kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Reliability and Accuracy of Standard Reference Procedures for Measurements of Trunk and Arm Postures in Ergonomics
Karolinska Inst, Inst Environm Med, Unit Occupat Med, S-17177 Stockholm, Sweden..
Karolinska Inst, Inst Environm Med, Unit Occupat Med, S-17177 Stockholm, Sweden.;Stockholm Cty Council, Ctr Occupat & Environm Med, S-11365 Stockholm, Sweden.;Chalmers Univ Technol, Dept Ind & Mat Sci, S-41296 Gothenburg, Sweden..ORCID-id: 0000-0002-5616-3568
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Medicinteknik och hälsosystem, Ergonomi. Karolinska Inst, Inst Environm Med, Unit Occupat Med, S-17177 Stockholm, Sweden.; Stockholm City Council, Ctr Occupat & Environm Med, S-11365 Stockholm, Sweden.ORCID-id: 0000-0001-5777-4232
2025 (Engelska)Ingår i: Bioengineering, E-ISSN 2306-5354, Vol. 12, nr 1, artikel-id 50Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Adequate reference procedures for obtaining the reference zero-angle position are important for precise and accurate posture measurements, but few studies have systematically investigated these. A limited number of previous studies suggest differences in accuracy between procedures, with some causing an underestimation of the true arm elevation angle when sensors are taped to the skin. The reliability of commonly used reference procedures for the measurement of the trunk posture is also not well explored, and alternative procedures may improve precision. Based on this identified gap, this study evaluated the test-retest reliability of the N-position (I-pose), i.e., the standard procedure for recording trunk postures, and compared it with two new alternative procedures. Additionally, the accuracy of the N-position for measuring arm elevation angles was compared with one alternative procedure. A total of 40 participants (22 women and 18 men) aged 26-70 years performed the reference procedures in a laboratory setting. Postures were recorded using a smart workwear system equipped with two inertial measurement units (IMUs) embedded in pockets within the workwear. For the trunk posture, the N-position showed a slight lack of test-retest reliability, while one of the alternative procedures demonstrated better test-retest reliability. For the arm posture, the N-position, which does not include lateral trunk inclination, resulted in a substantial underestimation of the arm elevation angle of approximately 15 degrees, which is a novel finding. In contrast, the posture involving trunk inclination closely matched the targeted reference, with a difference of less than 2 degrees. This study underscores the importance of selecting appropriate reference procedures to ensure precise and accurate posture measurements.

Ort, förlag, år, upplaga, sidor
MDPI AG , 2025. Vol. 12, nr 1, artikel-id 50
Nyckelord [en]
measurement error, measurement bias, work postures, calibration procedures, posture assessment, standard posture, plumb line test, normal standing position, inclinometry, wearables
Nationell ämneskategori
Arbetsmedicin och miljömedicin
Identifikatorer
URN: urn:nbn:se:kth:diva-359808DOI: 10.3390/bioengineering12010050ISI: 001404651000001PubMedID: 39851325Scopus ID: 2-s2.0-85216017838OAI: oai:DiVA.org:kth-359808DiVA, id: diva2:1937064
Anmärkning

QC 20250212

Tillgänglig från: 2025-02-12 Skapad: 2025-02-12 Senast uppdaterad: 2025-02-12Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Forsman, Mikael

Sök vidare i DiVA

Av författaren/redaktören
Rhen, Ida-MartaForsman, Mikael
Av organisationen
Ergonomi
I samma tidskrift
Bioengineering
Arbetsmedicin och miljömedicin

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 101 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf