kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Monitoring Acetone with Photoacoustic Spectroscopy Using a Metal–Organic Framework
Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, P. R. China; Taizhou Hospital, Zhejiang University, Taizhou, 318000, P. R. China.
Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, P. R. China.
Taizhou Hospital, Zhejiang University, Taizhou, 318000, P. R. China.
Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, P. R. China.
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: Advanced Optical Materials, ISSN 2162-7568, E-ISSN 2195-1071, Vol. 12, nr 10, artikel-id 2302280Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Herein, this study describes a sample preconcentration apparatus based on a metal–organic framework (MOF) of NH2-UIO-66@PDMS adsorbent, which is first coupled to photoacoustic spectroscopy (PAS) technology for detection of acetone. The MOF selectively traps acetone out of complex samples and releases it into the photoacoustic (PA) cell, where PA signal intensity is recorded by PAS sensing system based on a cheap amplitude modulated UV LED as light source. The signal intensity is enhanced by 11 times after preconcentration of NH2-UIO-66@PDMS (100 mg). The preconcentration apparatus not only enhances sensitivity of sensor, but also promotes the anti-interference ability for common interferents (carbon dioxide, oxygen and water vapor, ethanol, propanol, etc.) of the sensor. As expected, the established PA sensor possesses a detection limit of 0.23 ppm for measuring acetone, which can feasibly be applied for the analysis of acetone in patients breath samples. This work provides a good example of the preconcentration effect of MOF for promoting PA sensor analytical performance, and the prospect of medical diagnosis.

Ort, förlag, år, upplaga, sidor
Wiley , 2024. Vol. 12, nr 10, artikel-id 2302280
Nyckelord [en]
acetone, NH2-UIO-66@PDMS, photoacoustic sensor, preconcentration, UV LED
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:kth:diva-367017DOI: 10.1002/adom.202302280ISI: 001153384400001Scopus ID: 2-s2.0-85183620754OAI: oai:DiVA.org:kth-367017DiVA, id: diva2:1983951
Anmärkning

QC 20250714

Tillgänglig från: 2025-07-14 Skapad: 2025-07-14 Senast uppdaterad: 2025-07-14Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

He, Sailing

Sök vidare i DiVA

Av författaren/redaktören
He, Sailing
Av organisationen
Elektromagnetism och fusionsfysik
I samma tidskrift
Advanced Optical Materials
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 31 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf