kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Demonstrating the Analytical Potential of a Wearable Microneedle-Based Device for Intradermal CO2 Detection
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Kemi, Tillämpad fysikalisk kemi. UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain.
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Kemi, Tillämpad fysikalisk kemi.ORCID-id: 0000-0002-6128-5340
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Kemi, Tillämpad fysikalisk kemi. UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain.ORCID-id: 0000-0002-4648-1861
Section of Neuropharmacology and Addiction Research, Department of Pharmaceutical Biosciences, Uppsala University, Uppsala 753 10, Sweden.
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: ACS Sensors, E-ISSN 2379-3694, Vol. 9, nr 1, s. 361-370Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Monitoring of carbon dioxide (CO2) body levels is crucial under several clinical conditions (e.g., human intensive care and acid–base disorders). To date, painful and risky arterial blood punctures have been performed to obtain discrete CO2 measurements needed in clinical setups. Although noninvasive alternatives have been proposed to assess CO2, these are currently limited to benchtop devices, requiring trained personnel, being tedious, and providing punctual information, among other disadvantages. To the best of our knowledge, the literature and market lack a wearable device for real-time, on-body monitoring of CO2. Accordingly, we have developed a microneedle (MN)-based sensor array, labeled as CO2–MN, comprising a combination of potentiometric pH- and carbonate (CO32–)-selective electrodes together with the reference electrode. The CO2–MN is built on an epidermal patch that allows it to reach the stratum corneum of the skin, measuring pH and CO32– concentrations directly into the interstitial fluid (ISF). The levels for the pH–CO32– tandem are then used to estimate the PCO2 in the ISF. Assessing the response of each individual MN, we found adequate response time (t95 < 5s), sensitivity (50.4 and −24.6 mV dec–1 for pH and CO32–, respectively), and stability (1.6 mV h–1 for pH and 2.1 mV h–1 for CO32–). We validated the intradermal measurements of CO2 at the ex vivo level, using pieces of rat skin, and then, with in vivo assays in anesthetized rats, showing the suitability of the CO2–MN wearable device for on-body measurements. A good correlation between ISF and blood CO2 concentrations was observed, demonstrating the high potential of the developed MN sensing technology as an alternative to blood-based analysis in the near future. Moreover, these results open new horizons in the noninvasive, real-time monitoring of CO2 as well as other clinically relevant gases. 

Ort, förlag, år, upplaga, sidor
American Chemical Society (ACS) , 2024. Vol. 9, nr 1, s. 361-370
Nyckelord [en]
blood correlation, CO2 sensing, in vivo measurements, interstitial fluid, ion-selective microneedles, wearable sensor
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:kth:diva-367150DOI: 10.1021/acssensors.3c02086ISI: 001152678300001PubMedID: 38175931Scopus ID: 2-s2.0-85182013919OAI: oai:DiVA.org:kth-367150DiVA, id: diva2:1984224
Anmärkning

QC 20250715

Tillgänglig från: 2025-07-15 Skapad: 2025-07-15 Senast uppdaterad: 2025-07-15Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Molinero-Fernandez, AguedaWang, QianyuXuan, XingCrespo, Gaston A.Cuartero, Maria

Sök vidare i DiVA

Av författaren/redaktören
Molinero-Fernandez, AguedaWang, QianyuXuan, XingCrespo, Gaston A.Cuartero, Maria
Av organisationen
Tillämpad fysikalisk kemi
I samma tidskrift
ACS Sensors
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 82 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf