kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Electrochemical dual-sensing of lactate and glucose using NiO nanoparticles with cross-sensitivity calibration
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Proteinvetenskap, Nanobioteknologi. KTH, Centra, Science for Life Laboratory, SciLifeLab. Division of Nanobiotechnology, Department of Protein Science, Science for Life LaAIMES, Center for the Advancement of Integrated Medical and Engineering Sciences, Department of Neuroscience, Karolinska Institute, Solna, Sweden.ORCID-id: 0000-0002-8245-692x
Department of Chemistry, Materials, and Chemical Engineering “G. Natta”, Politecnico di Milano, Milan, Italy.
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Proteinvetenskap, Nanobioteknologi. KTH, Centra, Science for Life Laboratory, SciLifeLab.
KTH, Centra, Science for Life Laboratory, SciLifeLab. KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Proteinvetenskap, Nanobioteknologi.ORCID-id: 0009-0007-4491-7223
Visa övriga samt affilieringar
2026 (Engelska)Ingår i: Talanta: The International Journal of Pure and Applied Analytical Chemistry, ISSN 0039-9140, E-ISSN 1873-3573, Vol. 297, artikel-id 128678Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Detection and monitoring of lactate and glucose levels in biological fluids and cell cultures are essential for understanding metabolic disorders. While electrochemical biosensors are commonly used, traditional enzymatic sensors face challenges related to stability, reproducibility, and cost. To address these limitations, we developed non-enzymatic sensors for lactate and glucose detection using nanostructured nickel oxide (NiO)–modified screen-printed carbon electrodes. The sensors were fabricated by drop-casting a NiO/Nafion/ethanol dispersion onto the working electrode, and their performance was evaluated using cyclic voltammetry and amperometry. Optimal sensitivity and linearity were achieved at a working potential of ∼0.5 V. The sensors exhibited linear responses for both lactate and glucose in the 0.1–5 mM range, with detection limits of 0.03 mM (lactate) and 0.025 mM (glucose), and sensitivities of 1.564 μA/mM (lactate) and 1.842 μA/mM (glucose) in 0.1 M NaOH–KCl electrolyte. To address glucose interference in lactate sensing, dual-sensing strategies were employed by varying Nafion concentration, applying differential potentials, or modifying the sensors with Prussian Blue to achieve selective detection. Validation against commercial lactate and glucose assay kits in cell culture medium showed good agreement, confirming the sensors’ accuracy. Finally, the sensor was integrated with a microfluidic chip, demonstrating its potential as a flow-through, enzyme-free metabolic sensor for future organ-on-a-chip applications.

Ort, förlag, år, upplaga, sidor
Elsevier BV , 2026. Vol. 297, artikel-id 128678
Nyckelord [en]
Dual-sensing, Electrochemical sensor, Enzyme-free, Glucose, Lactate, Microfluidics, Nickel oxide
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:kth:diva-369347DOI: 10.1016/j.talanta.2025.128678ISI: 001555926100002PubMedID: 40818303Scopus ID: 2-s2.0-105013133859OAI: oai:DiVA.org:kth-369347DiVA, id: diva2:1995115
Anmärkning

QC 20250904

Tillgänglig från: 2025-09-04 Skapad: 2025-09-04 Senast uppdaterad: 2025-09-04Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Nasiri, RohollahSanei, ReyhanehTanriverdi, SelimJain, SaumeyFayazbakhsh, FarzanehJönsson, Håkan N.Russom, AmanHerland, Anna

Sök vidare i DiVA

Av författaren/redaktören
Nasiri, RohollahVan Gastel, DirkjeSanei, ReyhanehTanriverdi, SelimJain, SaumeyFayazbakhsh, FarzanehJönsson, Håkan N.Russom, AmanHerland, Anna
Av organisationen
NanobioteknologiScience for Life Laboratory, SciLifeLabMikro- och nanosystemteknik
I samma tidskrift
Talanta: The International Journal of Pure and Applied Analytical Chemistry
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 63 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf