kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
The effect of temperature and load as a stressor for proton exchange membrane fuel cells durability at intermediate temperatures
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Kemiteknik, Tillämpad elektrokemi.ORCID-id: 0000-0003-4770-9554
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Kemiteknik, Tillämpad elektrokemi.ORCID-id: 0000-0001-5755-7967
Materials Science and Engineering Department, University of Connecticut, CT 06269-3136, Storrs, USA.
Department of Physics and Competence Centre for Catalysis, Chalmers University of Technology, SE-412 96 Göteborg, Sweden.
Visa övriga samt affilieringar
2025 (Engelska)Ingår i: Journal of Power Sources, ISSN 0378-7753, E-ISSN 1873-2755, Vol. 658, artikel-id 238258Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

To improve the Proton Exchange Membrane Fuel Cells (PEMFCs) suitability for heavy-duty vehicles a higher operating temperature is required. However, a higher operating temperature is often associated with higher degradation rates. In this work we investigate the effects of temperature and load on the degradation of commercial state-of-the-art membrane electrode assemblies (MEAs) operating at intermediate temperatures (IT) between 80 and 120 °C during galvanostatic holds. Thorough electrochemical analysis was made together with transmission electron microscopy and modelling. As expected, a more rapid decrease in performance is observed at an increased operating temperature. The main loss in performance is linked to changes in the membrane and ionomer in the membrane electrode assembly. In particular, the membranes fail due to pinhole formation, resulting in higher hydrogen crossover. It is also seen that the ionomer in the cathode degrades faster at elevated temperatures, and that a lower applied load reduces the rate. Further analysis shows small and similar changes in the electrode thickness and particle sizes for all temperatures. Although an elevated temperature reduces the lifetime of a fuel cell, operation at elevated temperatures for shorter durations can be feasible, but the polymer electrolytes must be designed for higher temperatures.

Ort, förlag, år, upplaga, sidor
Elsevier BV , 2025. Vol. 658, artikel-id 238258
Nationell ämneskategori
Energiteknik Annan kemiteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-372894DOI: 10.1016/j.jpowsour.2025.238258ISI: 001575358500002Scopus ID: 2-s2.0-105020455987OAI: oai:DiVA.org:kth-372894DiVA, id: diva2:2013795
Anmärkning

QC 20251114

Tillgänglig från: 2025-11-14 Skapad: 2025-11-14 Senast uppdaterad: 2025-11-14Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Eriksson, BjörnButori, MartinaLagergren, CarinaWreland Lindström, RakelLindbergh, Göran

Sök vidare i DiVA

Av författaren/redaktören
Eriksson, BjörnButori, MartinaLagergren, CarinaWreland Lindström, RakelLindbergh, Göran
Av organisationen
Tillämpad elektrokemi
I samma tidskrift
Journal of Power Sources
EnergiteknikAnnan kemiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 87 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf