Detection of Thrombi in Extracorporeal Membrane Oxygenation Circuits Using Low-Frequency Acoustic Measurements
KTH, Skolan för teknikvetenskap (SCI), Teknisk mekanik, Strömningsmekanik. (FLOW)ORCID-id: 0009-0003-9375-1806
Department of Anaesthesia, Surgery and Intensive Care, Sundsvall Hospital, Region Västernorrland, Sundsvall, Sweden; Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, Sweden.
Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, Sweden; ECMO Centre Karolinska, Pediatric Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden.
KTH, Skolan för teknikvetenskap (SCI), Teknisk mekanik, Strömningsmekanik. (FLOW)ORCID-id: 0000-0001-9976-8316
Visa övriga samt affilieringar
2025 (Engelska)Ingår i: ASAIO journal (1992), ISSN 1058-2916, E-ISSN 1538-943XArtikel i tidskrift (Refereegranskat) Epub ahead of print
Abstract [en]

Extracorporeal membrane oxygenation (ECMO) provides temporary support for patients with severe acute cardiac or respiratory failure. Although thrombotic complications are common during ECMO, the real-time detection and management of thrombosis-related complications remain challenging. In this study, we introduce a noninvasive approach for detecting thrombi using an acoustic detection technique. The presence of blood clots in the ECMO circuit has been correlated with an increase in the amplitude of the acoustic spectrum <20 Hz. This amplification allows for the prediction of clots in the ECMO circuit using acoustic measurements. The predicted results were compared with visual observations, and the technique achieved a total accuracy of 84%. Hypothesizing that some of the false positives were indicators of clots in the circuitry, the accuracy may be up to 96%. This technique could be integrated with the existing clot detection method to enhance patient outcomes.

Ort, förlag, år, upplaga, sidor
Ovid Technologies (Wolters Kluwer Health) , 2025.
Nyckelord [en]
infra-sound, thrombi
Nationell ämneskategori
Hematologi Neurologi Anestesi och intensivvård
Identifikatorer
URN: urn:nbn:se:kth:diva-377331DOI: 10.1097/MAT.0000000000002661PubMedID: 41664281Scopus ID: 2-s2.0-105029721625OAI: oai:DiVA.org:kth-377331DiVA, id: diva2:2041900
Anmärkning

QC 20260226

Tillgänglig från: 2026-02-26 Skapad: 2026-02-26 Senast uppdaterad: 2026-02-26Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Nanayakkara, SheranPrahl Wittberg, Lisa

Sök vidare i DiVA

Av författaren/redaktören
Nanayakkara, SheranPrahl Wittberg, Lisa
Av organisationen
Strömningsmekanik
I samma tidskrift
ASAIO journal (1992)
HematologiNeurologiAnestesi och intensivvård

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 41 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf