kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Stood-up drop to determine receding contact angles
KTH, Skolan för teknikvetenskap (SCI), Teknisk mekanik, Strömningsmekanik.
Univ Twente, Max Planck Ctr Twente Complex Fluid Dynam, Phys Fluids Dept, Dept Sci & Technol, POB 217, NL-7500 AE Enschede, Netherlands.
Max Planck Inst Polymer Res, Ackermannweg 10, D-55128 Mainz, Germany.
Max Planck Inst Polymer Res, Ackermannweg 10, D-55128 Mainz, Germany.
Visa övriga samt affilieringar
2026 (Engelska)Ingår i: Soft Matter, ISSN 1744-683X, E-ISSN 1744-6848, Vol. 22, nr 3, s. 657-667Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The wetting behavior of drops on natural and industrial surfaces is determined by the advancing and receding contact angles. They are commonly measured by the sessile drop technique, also called goniometry, which doses liquid through a solid needle. Consequently, this method requires substantial drop volumes, long contact times, tends to be user-dependent, and is difficult to automate. Here, we propose the stood-up drop (SUD) technique as an alternative to measure receding contact angles. The method consists of depositing a liquid drop on a surface by a short liquid jet, at which it spreads radially forming a pancake-shaped film. Then the liquid retracts, forming a spherical cap drop shape (stood-up drop). At this quasi-equilibrium state, the contact angle (theta SUD) closely resembles the receding contact angle measured by goniometry. Our method is suitable for a wide variety of surfaces from hydrophilic to hydrophobic, overcoming typical complications of goniometry such as needle-induced distortion of the drop shape, and it reduces user dependence. We delineate when the receding contact angle can be obtained by the stood-up method using volume-of-fluid (VoF) simulations that systematically vary viscosity, contact angle, and deposited drop volume. Finally, we provide simple scaling criteria to predict when the stood-up drop technique works.

Ort, förlag, år, upplaga, sidor
Royal Society of Chemistry (RSC) , 2026. Vol. 22, nr 3, s. 657-667
Nationell ämneskategori
Metallurgi och metalliska material Strömningsmekanik
Identifikatorer
URN: urn:nbn:se:kth:diva-377484DOI: 10.1039/d5sm00985eISI: 001643908400001PubMedID: 41427957Scopus ID: 2-s2.0-105025241475OAI: oai:DiVA.org:kth-377484DiVA, id: diva2:2042980
Anmärkning

QC 20260303

Tillgänglig från: 2026-03-03 Skapad: 2026-03-03 Senast uppdaterad: 2026-03-03Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Diaz, Diego Ignacio

Sök vidare i DiVA

Av författaren/redaktören
Diaz, Diego Ignacio
Av organisationen
Strömningsmekanik
I samma tidskrift
Soft Matter
Metallurgi och metalliska materialStrömningsmekanik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 28 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf