Power balancing techniques in a micro-grid system
KTH, Skolan för elektroteknik och datavetenskap (EECS), Elkraftteknik.
Electrical Engineering, University at Buffalo (UB), Buffalo, NY, 14260, USA.
Department of Electrical and Electronic Engineering, Bangladesh University of Business and Technology (BUBT), Dhaka, 1216, Bangladesh.
Department of Electrical and Electronic Engineering, Bangladesh University of Business and Technology (BUBT), Dhaka, 1216, Bangladesh.
Visa övriga samt affilieringar
2026 (Engelska)Ingår i: Electric power systems research, ISSN 0378-7796, E-ISSN 1873-2046, Vol. 257, artikel-id 112987Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The growing use of renewable energy in microgrids introduces uncertainty due to the variable nature of wind and solar generation. This study evaluates the reliability of a benchmark low-voltage microgrid using a probabilistic framework based on Monte Carlo Simulation and statistical modeling of load demand, wind speed, and solar irradiance. System adequacy is assessed using the Expected Energy Not Served (EENS) index. Three mitigation options are examined under the same stochastic conditions: installation of a micro-turbine with renewable curtailment, implementation of demand-side management (DSM), and integration of energy storage. A ten-year economic comparison is also performed to assess long-term feasibility. The results show that renewable generation alone does not fully eliminate supply shortages. DSM reduces deficits effectively with relatively low investment, while the micro-turbine improves reliability at higher capital cost. The contribution of energy storage depends strongly on installed capacity, and under the considered rating, its impact is limited during prolonged deficit periods. The study provides a consistent technical and economic comparison of alternative strategies for improving reliability in renewable-based microgrids.

Ort, förlag, år, upplaga, sidor
Elsevier BV , 2026. Vol. 257, artikel-id 112987
Nyckelord [en]
Energy management, Microgrid, Monte Carlo simulation, Reliability assessment
Nationell ämneskategori
Energisystem Energiteknik Annan elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:kth:diva-380077DOI: 10.1016/j.epsr.2026.112987ISI: 001731080800001Scopus ID: 2-s2.0-105034042672OAI: oai:DiVA.org:kth-380077DiVA, id: diva2:2055064
Anmärkning

QC 20260422

Tillgänglig från: 2026-04-22 Skapad: 2026-04-22 Senast uppdaterad: 2026-04-22Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Khan, Md Nazmus Shakib

Sök vidare i DiVA

Av författaren/redaktören
Khan, Md Nazmus Shakib
Av organisationen
Elkraftteknik
I samma tidskrift
Electric power systems research
EnergisystemEnergiteknikAnnan elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 14 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf