kth.sePublikationer KTH
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
On Design of a Compact Primary Switched Conversion System for Electric Railway Propulsion
KTH, Skolan för elektro- och systemteknik (EES), Elektriska maskiner och effektelektronik.
2009 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

In this thesis, a compact and light primary switched conversion system for AC-fed railway propulsion is investigated. It is characterized by soft switching of all converter stages and a source commutated primary converter comprising series connected valves. Both weight and volume of the conversion system are reduced significantly compared to a conventional system with a low frequency transformer.

The conversion system is made up of N isolated AC/DC conversion cells, each comprising a cycloconverter and a voltage source converter (VSC) coupled by a medium frequency transformer. The cells are series connected on the AC side and connected to a common DC-link. Thus, 2N+1 voltage levels can be synthesized at the AC terminal and the voltage stress on the transformer and line filter is reduced compared to a one cell solution. Series connection of semiconductor valves allows independent choice of blocking voltage and number of converter cells. Choosing two converter cells is an attractive compromise. Five level output reduces the harmonic distortion and simplify transformer and line filter design while keeping the complexity of the conversion system low.

The mutually commutated converter (MCC) allows a transformer frequency in the range of 4 to 8 kHz without derating the line side converter due to zero voltage switching of the VSC. Modern magnetic materials, like high silicon steel, amorphous and noncrystalline materials allow design of the transformer with high efficiency at elevated frequencies.

In a 15 kV system, the peak voltage at the catenary is typically beyond 32 kV which is far beyond the voltage capability of currently available semiconductors. Therefore, several semiconductors are connected in series. Favourable commutation conditions and a new gate drive arrangement allow snubberless commutation of the primary converter stage. Thus, the primary converter can be highly integrated, reducing both weight and volume. The conversion system can be placed on the roof or in the underframe without compromising efficiency or vehicle performance.

The feasibility of the conversion concept has been demonstrated by means of a down-scaled prototype. Snubberless commutation of series connected valves is demonstrated.

Ort, förlag, år, upplaga, sidor
Stockholm: KTH , 2009. , s. viii, 75
Serie
Trita-EE, ISSN 1653-5146 ; 2009 : 29
Nyckelord [en]
Isolated AC/DC converter, Mutual commutation, Soft Switching, Cyclo converter, Medium-Frequency Transformer, Electric Railway Propulsion
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:kth:diva-10428ISBN: 978-91-7415-327-9 (tryckt)OAI: oai:DiVA.org:kth-10428DiVA, id: diva2:217187
Disputation
2009-06-05, D3, Lindstedtvägen 5, KTH, Stockholm, 10:00 (Engelska)
Opponent
Handledare
Anmärkning
QC 20100723Tillgänglig från: 2009-05-18 Skapad: 2009-05-13 Senast uppdaterad: 2022-06-25Bibliografiskt granskad
Delarbeten
1. Design Considerations for a Medium Frequency Transformer in a Line Side Power Conversion System
Öppna denna publikation i ny flik eller fönster >>Design Considerations for a Medium Frequency Transformer in a Line Side Power Conversion System
2004 (Engelska)Ingår i: Proceedings of the 35th Annual IEEE Power Electronics Specialist Conference, PESC 2004, IEEE , 2004, s. 704-710Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Design considerations are presented for a medium frequency transformer in a line side power conversion system for electric railway traction. The system employs soft commutation in order to reduce switching losses and allow for high operating frequency of the transformer. Two different designs are evaluated; The first one is dry insulated and the second one is liquid-immersed. Calculations indicate that a 1 MVA transformer operating at 4 kHz could be realized with an active weight of below 150 kg for both dry and liquid-immersed transformer concepts. The transformers are modeled magnetically, electrically and thermally, and a geometric optimization procedure based on a cost function is applied to achieve an optimum design.

Ort, förlag, år, upplaga, sidor
IEEE, 2004
Serie
IEEE power electronics specialists conference records, ISSN 0275-9306
Nyckelord
Boundary layers, Dielectric materials, Electric commutation, Electric insulation, Electric railroads, Electric traction, Gravitational effects, Heat flux, Heat transfer coefficients Power converters, Switching
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
urn:nbn:se:kth:diva-10422 (URN)10.1109/PESC.2004.1355834 (DOI)000224587600113 ()2-s2.0-8744291981 (Scopus ID)0-7803-8399-0 (ISBN)
Anmärkning

QC 20100723

Tillgänglig från: 2009-05-13 Skapad: 2009-05-13 Senast uppdaterad: 2026-10-09Bibliografiskt granskad
2. Switching Frequency Limit for Soft-Switching MF Transformer System for AC-fed Traction
Öppna denna publikation i ny flik eller fönster >>Switching Frequency Limit for Soft-Switching MF Transformer System for AC-fed Traction
2005 (Engelska)Ingår i: Proceesings of the 36th Annual IEEE Power Electronics Specialist Conference, PESC 2005, IEEE , 2005, s. 1678-1684Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

The migration to line side power conversion topologies comprising a medium frequency transformer in AC-fed propulsion systems may reduce size and weight of the conversion system. The switching frequency is a crucial factor affecting the viability of such a conversion system. An increased switching frequency of a mutually commutated conversion system comprising a medium frequency transformer employing soft switching is verified by single pulse measurements. A test bench to characterize standard IGBT modules under soft switching has been build and loss measurements on a 3.3 kV IGBT module are presented for hard and soft switching. A loss model of the investigated topology is developed and the maximum switching frequency for a converter equipped with the investigated module is estimated for hard and soft switching.

Ort, förlag, år, upplaga, sidor
IEEE, 2005
Serie
IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE RECORDS, ISSN 0275-9306
Nyckelord
Analog to digital conversion; Electric losses; Electric network topology; Electric traction; Electric transformers
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
urn:nbn:se:kth:diva-10423 (URN)10.1109/PESC.2005.1581856 (DOI)000237036501109 ()2-s2.0-33847758986 (Scopus ID)0-7803-9033-4 (ISBN)
Konferens
36th Annual IEEE Power Electronic Specialists Conference (PESC 05). Recife, BRAZIL. JUN 12-16, 2005
Anmärkning

QC 20100723

Tillgänglig från: 2009-05-13 Skapad: 2009-05-13 Senast uppdaterad: 2026-10-09Bibliografiskt granskad
3. Harmonic Mitigation in Single Phase Mutually Commutated Converter Systems
Öppna denna publikation i ny flik eller fönster >>Harmonic Mitigation in Single Phase Mutually Commutated Converter Systems
2006 (Engelska)Ingår i: Proceedings of the 37th Annual IEEE Power Electronics Specialists Conference, PESC 2006, NEW YORK, NY: IEEE , 2006, s. 1542-1548Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

An AC/DC converter comprising a cycloconverter and a capacitively snubbered voltage source converter (VSC), coupled by a medium frequency transformer, offers significant advantages. Bidirectional AC/DC power flow as well as voltage transformation and isolation can be achieved. By mutual commutation of the converters, soft switching can be achieved for all semiconductors, thus, link frequency can be increased, allowing smaller transformer and reduced filter components. However, the mutual commutation scheme imposed by the soft switching requirement puts constraints on the PWM pattern causing low frequency harmonics in certain operating points. It is shown that the low frequency harmonics can be eliminated for all points of operation, both in a single bridge configuration and interlaced configuration, common in AC-fed propulsion. A sub-optimal harmonic mitigation method based on a regularly sampled modulator is proposed. By proper oversampling of the reference waveforms substantial reduction of the low frequency harmonic contents can be achieved. The mitigation method is verified by circuit simulation and the feasibility to propulsion is demonstrated.

Ort, förlag, år, upplaga, sidor
NEW YORK, NY: IEEE, 2006
Serie
IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE RECORDS, ISSN 0275-9306
Nyckelord
Electric transformers; Harmonic analysis; Switching
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
urn:nbn:se:kth:diva-10424 (URN)10.1109/PESC.2006.1712205 (DOI)000245402503017 ()2-s2.0-42449148709 (Scopus ID)0-7803-9716-9 (ISBN)
Konferens
37th IEEE Power Electronics Specialist Conference (PESC 2006). Cheju Isl, SOUTH KOREA. JUN 18-22, 2006
Anmärkning
QC 20100723Tillgänglig från: 2009-05-13 Skapad: 2009-05-13 Senast uppdaterad: 2022-06-25Bibliografiskt granskad
4. Active Snubber Circuit for Source Commutated Converters Utilizing the IGBT in the Linear Region
Öppna denna publikation i ny flik eller fönster >>Active Snubber Circuit for Source Commutated Converters Utilizing the IGBT in the Linear Region
2008 (Engelska)Ingår i: IEEE transactions on power electronics, ISSN 0885-8993, E-ISSN 1941-0107, Vol. 23, nr 5, s. 2595-2601Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

This paper describes a gate control method where an IGBT is controlled in its linear region by means of closed loop control in order to regulate the voltage slope during turn-on and to clamp the voltage of an anti-parallel diode in a source commutated converter. Controlling the voltage slope may be necessary in a high voltage converter to avoid emission of EMI or to avoid triggering oscillations which may cause insulation failure. Controlling the switching trajectory without influence from the device characteristics is important where series-connection is necessary to increase the overall blocking voltage. The control method has been verified by means of a prototype.

Ort, förlag, år, upplaga, sidor
IEEE, 2008
Nyckelord
Ac-ac power conversion; Electromagnetic interference; Insulated gate bipolar transistors; Snubbers
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
urn:nbn:se:kth:diva-10425 (URN)10.1109/TPEL.2008.2002093 (DOI)000261599700038 ()2-s2.0-57349189392 (Scopus ID)
Anmärkning

QC 20150624

Tillgänglig från: 2009-05-13 Skapad: 2009-05-13 Senast uppdaterad: 2026-10-07Bibliografiskt granskad
5. Thermal Evaluation of a Medium Frequency Transformer in a Line Sider Conversion System
Öppna denna publikation i ny flik eller fönster >>Thermal Evaluation of a Medium Frequency Transformer in a Line Sider Conversion System
2009 (Engelska)Ingår i: Proceedings of the 13th International European Electronics Conference and Exhibition, EPE '09, IEEE , 2009, s. 2517-2526Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

A central part of a medium frequency conversion system is the transformer. A medium frequency transformer for railway propulsion may be stressed beyond 30kV with voltage slopes around 50kV/mu s depending on topology while the geometric dimensions are small. A 170kVA transformer prototype operated at 4 kHz has been developed and tested.

A transient thermal model of the transformer is developed and verified experimentally. The transient thermal behavior is important in propulsion applications where the conversion system is often heavily overloaded. Simulations indicate that the overloading capability of the transformer is comparable to a conventional traction transformer. Experimental results are in good agreement with the model.

Ort, förlag, år, upplaga, sidor
IEEE, 2009
Nyckelord
Transformer, High frequency power converter, Thermal design, Rail vehicle
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
urn:nbn:se:kth:diva-10426 (URN)000275384101045 ()2-s2.0-72949091735 (Scopus ID)978-1-4244-4432-8 (ISBN)
Konferens
2009 13th European Conference on Power Electronics and Applications, EPE '09; Barcelona; 8 September 2009 through 10 September 2009
Anmärkning

QC 20110304

Tillgänglig från: 2009-05-13 Skapad: 2009-05-13 Senast uppdaterad: 2026-10-09Bibliografiskt granskad

Open Access i DiVA

fulltext(823 kB)1895 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 823 kBChecksumma SHA-512
ba8a924dd8809df602a627bce362b9bf5e36aee03f03dcc2f88ad2353c706f0756e5d42e3f516dbb18b3797dcac9d4887253b2c23e6ab72b336955e874aac87f
Typ fulltextMimetyp application/pdf
spikblad(117 kB)194 nedladdningar
Filinformation
Filnamn SPIKBLAD01.pdfFilstorlek 117 kBChecksumma SHA-512
6c787176407c26e84d15bd798740901620d0e65e5d094591b1ce7b8472eda67032db8b2fe8cb21eb957e81d9c28c76db78a110847e180495ef3db9107bea70c5
Typ spikbladMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Kjellqvist, Tommy
Av organisationen
Elektriska maskiner och effektelektronik
Annan elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 1896 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 1511 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf