kth.sePublikationer KTH
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Membrane Distillation pilot tests for different wastewaters: Separation of pharmaceutical residues and treatment of flue gas condensate with Xzero Membrane Distillation in Pilot Scale at Hammarby Sjöstadsverk
IVL Svenska Miljöinstitutet/IVL Swedish Environmental Research.
IVL Svenska Miljöinstitutet/IVL Swedish Environmental Research.
IVL Svenska Miljöinstitutet/IVL Swedish Environmental Research.
IVL Svenska Miljöinstitutet/IVL Swedish Environmental Research.
Visa övriga samt affilieringar
2015 (Engelska)Rapport (Refereegranskat)
Abstract [en]

The purpose of the project was to evaluate membrane distillation as an alternative separation technology for different water purification applications. Membrane distillation (MD) is a unit operation that uses water repellent (hydrophobic) membranes as a barrier for contaminated water. The driving force for the process is the vapor pressure over the membrane achieved by applying temperature differences between a warm and a cold side. The process takes place at temperatures below 100 °C and at ambient pressure. Pilot studies were performed at Hammarby Sjöstadsverk to test the separation of pharmaceutical residues from municipal wastewater after biological treatment as well as final treatment of flue gas condensate. In both cases, most target compounds were separated to a very high degree, often more than 90 %. The project also included energy studies that showed some potential for energy optimisation of the current equipment and provided input for energy efficient set-up, e.g. by using waste heat such as the return flow from district heating. Varying results for the single modules also indicated optimisation potential. The project was performed in cooperation between IVL Swedish Environmental Research Institute, Xzero AB as technology provider, and KTH (Royal institute of technology) for energy studies

Ort, förlag, år, upplaga, sidor
Stockholm: IVL Swedish Environmental Research Institute , 2015. , s. 45
Nyckelord [en]
Membrane distillation, Wastewater, Flue gas, Pharmaceuticals, Energy analysis, Removal performance
Nationell ämneskategori
Energiteknik
Forskningsämne
Energiteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-182495OAI: oai:DiVA.org:kth-182495DiVA, id: diva2:904623
Anmärkning

QC 20160311

Tillgänglig från: 2016-02-19 Skapad: 2016-02-19 Senast uppdaterad: 2024-03-15Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Report/IVL

Person

Martin, AndrewWoldemariam, Daniel

Sök vidare i DiVA

Av författaren/redaktören
Martin, AndrewWoldemariam, Daniel
Av organisationen
Kraft- och värmeteknologi
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 503 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf