Energy mapping of existing building stock in Sweden - Analysis of data from Energy Performance Certificates
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology. Vattenfall AB, Sverige.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology. Vattenfall AB, Sverige.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology. Vattenfall AB, Sverige.ORCID iD: 0000-0001-8169-9308
2017 (English)In: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 153, p. 341-355Article in journal (Refereed) Published
Abstract [en]

This study contributes to defining the current energy consumption baseline for buildings in Sweden. The data used for the analysis are extracted from the database of the Swedish National Board of Housing, Building and Planning and consists of 186,021 measured energy performance certificates issued for commercial buildings (355 Mm(2)), collected during 2007-2015. The results from this study for certain building types, construction periods, climate zones and energy use is presented. Building codes have influence of the buildings energy performance. When new building codes have been adopted and energy performance requirement been stricter the measured energy consumption have been lowered compared to buildings built earlier. New buildings have nevertheless often higher energy consumption than stipulated by the building code. Climate zone have less impact on energy consumption than type of building. Building units in the warmer climate zones generally have slightly lower energy consumption than those in colder zones. This implies that the buildings are well adapted to the climates at hand. The results may help public authorities to plan future business strategies and energy policies. The Swedish Energy Performance Certificates are quite reliable because they are based on energy bills and not on theoretical calculations.

Place, publisher, year, edition, pages
Elsevier, 2017. Vol. 153, p. 341-355
Keywords [en]
Energy performance certificates, Commercial buildings, Rental premises, Office, Schools, Healthcare, Sport, Hotels and restaurant, Industries
National Category
Building Technologies Energy Engineering
Identifiers
URN: urn:nbn:se:kth:diva-217189DOI: 10.1016/j.enbuild.2017.06.073ISI: 000412959600028Scopus ID: 2-s2.0-85027982956OAI: oai:DiVA.org:kth-217189DiVA, id: diva2:1154290
Funder
Knowledge FoundationVattenfall AB
Note

QC 20171102

Available from: 2017-11-02 Created: 2017-11-02 Last updated: 2026-02-12Bibliographically approved
In thesis
1. Energy Performance Certificates: Labelling in society and new buildings
Open this publication in new window or tab >>Energy Performance Certificates: Labelling in society and new buildings
2026 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Energy Labeling Buildings – A commentThis thesis investigates energy regulation in Sweden and its consequences forenergy efficiency in buildings.The first study and article contribute to defining the current energyconsumption baseline for buildings in Sweden. The data used for the analysisare extracted from the database of the Swedish National Board of Housing,Building and Planning and consists of 186,021 measured energy performancecertificates issued for commercial buildings (355 Mm2), collected during2007–2015.The results from that study for certain building types, construction periods,climate zones and energy use are presented. Building codes have influence onthe building’s energy performance. When new building codes have beenadopted and energy performance requirement have been stricter the measuredenergy consumption has been lowered compared to buildings built earlier.New buildings have nevertheless often higher energy consumption thanstipulated by the building code.The first Swedish Energy Performance Certificates (EPC) that were studiedwere quite reliable because they were based on energy bills and not ontheoretical calculations. This has now changed and are now aligned with EUregulation.The second article and study focuses on the Swedish building code regardingthe energy consumption of buildings, and the calculation of which should beincluded in a building permit. The energy performance certificate (EPC) of abuilding documents the actual energy performance, which provides anopportunity to compare the actual energy consumption with what was plannedand what was built. Here, this comparison is done for buildings in the city ofStockholm raised in the period from 2010 to 2015.

The first observation in this second study was that in official listings as thetaxation register, the EPC database and the building permits, data files aremissing. It would be useful to coordinate and develop the collaborationbetween different authorities and develop a national database with thisinformation.

However, for the buildings with summited documents the mean energyconsumption according to the EPCs is close to what has been requested in thebuilding code. So, in general, the building code is fulfilled.

When the energy consumption according to the EPC is lower than planned, theexplanation relates to changes or miscalculation in Atemp, erroneousventilation flow in calculations or that the EPCs are only based on calculations.For commercial buildings, such as restaurants, server halls, and sport facilitieswith various internal loads, there should be a focus on the total energy demandin building as one unit with the operations in the unit. The EPC should offer anopportunity for follow-up on the planned energy performance.

Abstract [sv]

Energimärkning av byggnader – En kommentar

Denna avhandling undersöker regler för energianvändning i byggnader iSverige och deras konsekvenser för energieffektivitet i byggnader.

Den första studien och artikeln bidrar till att definiera den nuvarande baslinjenför energiförbrukning för byggnader i Sverige. Data som används för analysenär hämtade från Boverkets databas och består av 186 021 uppmättaenergicertifikat utfärdade för kommersiella byggnader (355 Mm²), insamladeunder 2007–2015.

Resultaten från den studien för vissa byggnadstyper, byggperioder,klimatzoner och energianvändning presenteras. Byggnadsnormer påverkarbyggnadens energiprestanda. När nya byggregler har antagits och kraven påenergiprestanda blivit strängare har den uppmätta energiförbrukningen sänktsjämfört med tidigare byggda byggnader. Nya byggnader har dock ofta högreenergiförbrukning än vad byggreglerna föreskriver.

De första svenska energideklarationerna som studerades var ganskatillförlitliga eftersom de baserades på energiräkningar och inte på teoretiskaberäkningar. Det har nu ändrats och är nu anpassat till EU:s lagstiftning därberäknade värden används.

Den andra artikeln och studien fokuserar på den svenska byggnormenavseende byggnaders energiförbrukning och energiberäkningen som ingår somunderlag till bygglovet. Energideklarationen upprättas två år efter attbyggnaden är uppförd och dokumenterar den faktiska energiprestandan, vilketger möjlighet att jämföra den faktiska energiförbrukningen med det somplanerats och det som byggts. Här jämfördes underlag för byggnader iStockholms stad uppförda under perioden 2010 till 2015.

Den första observationen var att officiella listor från Skatteverket,energideklarationsdatabasen och bygglovsdatafilerna inte stämde överens - detsaknades underlag. Det vore bra att samordna och utveckla samarbetet mellanolika myndigheter och utveckla en nationell databas.

Men för byggnader med sammanställda dokument ligger den genomsnittligaenergiförbrukningen enligt energideklarationen nära vad som efterfrågats ibyggnormen och som redovisats i beräkningar vid bygglovsansökan. Så iallmänhet är byggreglerna uppfyllda.När energiförbrukningen enligt Energideklarationen (EPC) är lägre änplanerat, förklaras detta av förändringar eller felberäkningar i Atemp, felaktigtventilationsflöde i beräkningar eller att EPC:erna enbart baseras påberäkningar.

För kommersiella byggnader, såsom restauranger, serverhallar ochidrottsanläggningar med olika interna laster, bör det vara fokus på det totalaenergibehovet i byggnaden som en enhet med verksamheten i enheten. EPCbör erbjuda en möjlighet till uppföljning av den planerade energiprestanda.

Place, publisher, year, edition, pages
Stockholm: KTH Royal Institute of Technology, 2026. p. 53
Series
TRITA-ABE-DLT ; 265
Keywords
Core Topic & Purpose, Energy consumption baseline, Energy efficiency, Building energy performance, Data Sources & Material, Energy Performance Certificates (EPC), Swedish National Board of Housing, Building and Planning database, Measured certificates (186, 021), Secondary data (energy bills), Commercial buildings (355 Mm²), Collection period (2007–2015), Building-Related Factors, Building type, Construction year / period, Climate zone, Building codes / regulations, Energy performance requirements, Findings & Conclusions, Measured energy use/consumption, Limited impact of climate zone, Adaptation to local climate, New buildings vs. building code, Stricter requirements and lower consumption, Stakeholders & Application, Public authorities, Energy efficiency policy, Business strategy (for authorities), Energy policy planning, Data reliability
National Category
Civil Engineering
Research subject
Civil and Architectural Engineering, Building Technology
Identifiers
urn:nbn:se:kth:diva-376599 (URN)978-91-8106-536-7 (ISBN)
Presentation
2026-03-06, Stora konferensrummet, M108, Brinellvägen 23, KTH Campus, public video conference link [MISSING], Stockholm, 13:00 (Swedish)
Opponent
Supervisors
Funder
Knowledge FoundationVattenfall AB
Note

QC 20260216

Available from: 2026-02-16 Created: 2026-02-10 Last updated: 2026-02-16Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Björk, FolkeBerg, Magnusaf Klintberg, Tord

Search in DiVA

By author/editor
Hjortling, CamillaBjörk, FolkeBerg, Magnusaf Klintberg, Tord
By organisation
Building Technology
In the same journal
Energy and Buildings
Building TechnologiesEnergy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 1290 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf