kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
On ``Cavitation on Chip'' in Microfluidic Devices With Surface and Sidewall Roughness Elements
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Biomedical Engineering and Health Systems, Medical Imaging.ORCID iD: 0000-0003-4883-7347
Mechatronics Engineering Program, Faculty of Engineering and Natural Sciences, Sabanci University.ORCID iD: 0000-0002-6302-0004
Show others and affiliations
2019 (English)In: Journal of microelectromechanical systems, ISSN 1057-7157, E-ISSN 1941-0158, Vol. 28, no 5, p. 890-899Article in journal (Refereed) Published
Abstract [en]

In this paper, cavitating flows are characterized in 29 microfluidic devices in order to achieve a comprehensive perspective regarding flow patterns in microscale, which is crucial in the applications, such as energy harvesting and biomedical treatment. While the assessment of size effects is vital for the design and development of microfluidic devices involving phase change, surface/sidewall roughness and pressure pulses as a result of nanomechanical oscillations increase the performance with respect to cavitation by providing more cavitation bubbles. A typical device generates cavitating flows under different conditions (from inception to choked flow). In this device, a restrictive element and a big channel downstream of the restrictive element--where the cavitation is formed and developed--are included. The cavitating flows are obtained inside 24 sidewall roughened and 5 surface roughened/plain microfluidic devices at different pressure drops. The length and height of the sidewall roughness elements are varied to achieve the most optimum performance in terms of cavitation generation. Moreover, different surface roughened and plain devices are considered to provide a comprehensive overview of cavitation generation in microscale. The results show that sidewall roughness elements have a remarkable effect on the cavitation inception and flow patterns. [2019-0025] IEEE

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers Inc. , 2019. Vol. 28, no 5, p. 890-899
Keywords [en]
Cavitation, fully developed twin cavities., inception, microfluidic device, roughness, Energy harvesting, Flow patterns, Fluidic devices, Microfluidics, Surface roughness, Biomedical treatment, Cavitation inception, Design and Development, Different pressures, fully developed twin cavities, Micro-fluidic devices, Nanomechanical oscillations
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-263269DOI: 10.1109/JMEMS.2019.2925541ISI: 000489837100019Scopus ID: 2-s2.0-85069910140OAI: oai:DiVA.org:kth-263269DiVA, id: diva2:1368052
Note

QC 20191105

Available from: 2019-11-05 Created: 2019-11-05 Last updated: 2024-05-20Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Ghorbani, MortezaMotezakker, Ahmad Reza

Search in DiVA

By author/editor
Ghorbani, MortezaMotezakker, Ahmad Reza
By organisation
Medical Imaging
In the same journal
Journal of microelectromechanical systems
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 220 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf